2.
Select the management processors to upgrade.
3.
For each selected management processor, click
Browse
, and then select a firmware image file. You
can also manually enter the path to the firmware image.
4.
Click
Upgrade Firmware
.
During the firmware upgrade process, all buttons are deactivated to prevent navigation.
The selected management processors are upgraded. Although HPLOMIG enables you to upgrade
hundreds of management processors, only 25 management processors are upgraded simultaneously.
Network activity is considerable during this process.
If an upgrade fails, a message is displayed in the
Results
column, and the utility continues to upgrade
the other selected management processors.
5.
After the upgrade is complete, click
Next
.
Selecting directory configuration options
After you click
Next
in the
Upgrade Firmware on Management Processors
window, the next task is to
select the management processors to configure, and to specify the directory options to enable.
Procedure
1.
Navigate to the
Select the Desired Configuration
window if it is not already open.
338
Selecting directory configuration options