Server firmware file type details
• When you update the system ROM, you must use a signed image or the signed ROMPAQ image:
◦
Signed image example
:
http://<server.example.com:8080>/<wwwroot>/P79_1.00_10_25_2013.signed.flash
◦
Signed ROMPAQ image example
:
http://<server.example.com>/<wwwroot>/CPQPJ0612.A48
• The Power Management Controller, chassis firmware, and NVMe backplane files use the file
extension
.hex
. For example, the file name might be similar to
ABCD5S95.hex
.
• The System Programmable Logic Device (CPLD) firmware file uses the file extension
.vme
.
Viewing installed firmware information
Procedure
Click
Firmware & OS Software
in the navigation tree.
The
Installed Firmware
page displays firmware information for various server components. If the server
is powered off, the information on this page is current as of the last power off. Firmware information is
updated only when the server is powered on and POST is complete.
Firmware types
The firmware types listed on the
Installed Firmware
page vary based on the server model and
configuration.
For most servers, the system ROM and iLO firmware are listed. Other possible firmware options include
the following:
• Power Management Controller
• Server Platform Services Firmware
• Smart Array
• Intelligent Platform Abstraction Data
• Smart Storage Battery
• TPM or TM firmware
• SAS Programmable Logic Device
• System Programmable Logic Device
• Intelligent Provisioning
• Networking adapters
• NVMe Backplane firmware
• Innovation Engine (IE) firmware
• Drive firmware
Viewing installed firmware information
73