The Active VC is by default the VC in interconnect bay 1. If the system is at factory defaults,
the administrator passwords for OA and VC are on the labels affixed to the back of the chassis.
If the passwords have been reset, enter the new passwords.
9.
The wizard now validates the information you have entered. It performs the following tests:
•
Pings the active OA.
•
Verifies the OA password.
•
Verifies that that OA IP address is the active OA.
If any of these tests fail, verify the configuration of the OA and VC modules as described on
the failure report. (Failures are typically caused by entering an IP address or password
incorrectly.) If you need to re-enter information, select
Back
to return to the Confirming Onboard
Administrator and Virtual Connect Settings dialog box, where you can make your changes.
NOTE:
If the initialization of the credential manager fails, the wizard displays a message
asking you to initialize the credential manager manually. See
“Credential Manager initialization
for more information.
10. The wizard now verifies the OA firmware.
11. Set the iLO IP addresses. On the Get iLO IP Addresses dialog box, select the method you want
to use to set up iLO IP addresses. Use the space bar to select/deselect the check boxes.
To configure the iLO IP addresses in sequence, enter the first iLO IP address on the Set iLO IP
Addresses dialog box. For example, if 172.16.3.1 is the starting iLO IP address, the installer
116
Expanding an X9720 or X9320 10GbE cluster by an X9730 module