4.
On the Change OA Network Properties screen, set Enclosure IP to
Enable
and press
OK
to
Accept.
5.
On the Network Settings: OA1 Active screen, select
Accept All
and press
OK
.
6.
On the Enclosure Settings screen, select
Standby OA
and press
OK
.
7.
On the Network Settings:OA2 screen, navigate to
Active IPv4
and press
OK
.
8.
Set the IP address, subnet mask, and gateway (optional) and
Accept
the changes.
9.
On the Network Settings:OA2 screen, navigate to
Accept All
and press
OK
.
NOTE:
The following conditions can also make the install software unable to ping the OA:
•
VC is uplinked from X1 rather than X6 (be sure that X6 is used on X9730 systems)
•
A gateway is not defined for OA or blade
•
No L3 route from VC to OA
•
Duplicate IP is used for blade or OA
•
VC is already configured but blade 1 does not have a VC profile assigned
An X9370 blade boots, but the Installer cannot ping the VC
After the blade boots, the Installer reports that it cannot ping the VC and the
ip addr
command
reports only
eth0
and
eth1
. Networks
eth[2–7]
are not visible. To correct this situation, complete
the following steps:
1.
Power off the blade.
2.
Log into the VC module from another system on the network.