2 Million Imp - Preventive Maintenance Guide - HP Indigo press 5000
CA294-00570
rev 01
page 16 of 18
Figure 6 Vacuum pump vanes
1
1
3.
Clean the inside of the pump. See Figure 6.
4.
Install new vanes. See Figure 6.
5.
Reinstall the end plate and its five retaining screws with a new gasket from the maintenance
kit.
6.
Install new O-rings and clean filters. See Figure 5.
7.
Reinstall muffler box.
8.
Reconnect the fast-on tube.