Installation Manual
CA294-03070 rev 00
page 100 of 153
Installing the unwinder
Positioning the unwinder
1.
Place the unwinder on the floor platform at the input side of the ILP.
Figure 81 Moving the unwinder into its final position
1
Unwinder v6
2
Pallet jack
2.
Use a pallet jack to move the unwinder into position near the input side of the ILP to a
distance of between 30 - 40 cm from the ILP feed stepping plate assembly.
CAUTION:
When moving the unwinder, make sure to place the
pallet jack under the frame as shown in Figure 81.
Otherwise, the unwinder will be damaged.