Installation Manual
CA294-03070 rev 00
page 104 of 153
Figure 85 Aligning the unwinder with the ILP
1
Top unwinder exit roller
4
ILP input idler No.3
2 Unwinder
v6.0
5 ILP
3 Parallel
jig
10.
Reconfigure the Parallel jig to align the unwinder with the ILP.
11.
Mount the Parallel jig between the ILP input idler No. 3 (Figure 63-8, Figure 85) and the top
unwinder exit roller as shown in Figure 85.
The V-section should sit on the ILP roller, and the measuring gauge should be on the
unwinder roller.
12.
Move the jig along the length of the rollers.
Note the difference between the readings at the front and rear.
13.
If the difference between the readings is more than 0.1 mm
±
0.05, then readjust the position
of the unwinder.
14.
Re-check the level of the unwinder.
Re-adjust if necessary.
15.
Re-check the alignment of the unwinder to the ILP using the Parallel jig.
Re-align if necessary.
Unwinder electrical connections
NOTE:
The unwinder is manufactured by Hunkeler. All the cables for
the unwinder are supplied by Hunkeler with the unwinder.
1.
Connect the power cable between the unwinder and the nearest electrical outlet at
the wall.
2.
Connect the ground wire to mains ground cable in the electrical cabinet M1.