Installation Manual
CA294-03070 rev 00
page 11 of 153
Heading
Step
Reference
Procedure
Notes and
check
37.
install the ILP exit
stepping plate on
page 83
Install the ILP exit stepping plate assembly
to the ILP.
38.
align the ILP and
stepping plate
assembly on page 86
Align the ILP and stepping plate assembly
with the press. Verify gap between ILP exit
cover and web entrance cover at PE1 is
approximately 4-5 mm.
39.
Measure on page 87
Measure distance between stepping plate
front edge and PE1 front wall. Distance
should measure 30 mm.
40.
Release on page 88
Release (do not remove) six ILP alignment
plate locking screws.
41.
Lower four ILP feet until castors
approximately 5 mm above floor platform
and feet touch floor.
42.
level and align the
ILP on page 89
Level the the ILP
43.
Align the ILP using the parallel jig.
44.
level and align the
ILP exit stepping
plate rollers on page
94
Level and align the ILP exit stepping plate
rollers.
45.
Install the ILP feed
stepping plate on
page 96
Install the ILP feed stepping plate. Align
and level the stepping plate to the ILP.
46.
install the priming
rollers on page 99
Install the ILP priming rollers
47.
Installing the
unwinder on page
100
Position, install, level and align the
unwinder.
48.
align the unwinder on
page 103
Align the unwinder with the ILP feed
stepping plate.
Unwinder
(60 mins)
49.
Unwinder electrical
connections on page
104
Install and connect all appropriate wiring
and air hoses.
50.
ILP electrical
connections on page
105
Install cables between the ILP connections
panel and cabinet M1.
51.
Install on page 105
Install cables between cabinet M1and the
ILP connections panel
52.
Connect on page 105
Connect air hoses and cables to the ILP
connections panel
53.
Install on page 106
Install the cable securing clamps on the
clamp rail.
ILP wiring and
air hose
connections
(160 mins)