Installation Manual
CA294-03070 rev 00
page 62 of 153
Cable
From end point elect. cab. M2
To end point elec. cab. M1
Notes
CA261-10910
cable 10910
CC413
Signal interface between cabinets at
X50
X50
connector
-
GND05
Ground connection cable M1b
Ground connection cable M1b
Route cable from
cabinet M1 to M2
4.
Install the electrical cabinet-to-cabinet cables as follows (Figure 44, Figure 45):
Cable
From end point elect. cab. M1
To end point elec. cab. M2
Notes
CA261-10190
JX15
connection Pins 1, 2
X15
connection at Pins 1, 2
-
-
X8
connector, pins 1,2,3,N,Pe
3-phase power supply for PE1 at
JX8
-
-
X9
connector, pins 1,2,3,N,Pe
3-phase power supply for PE2 at
JX9
-
5.
Install the electrical cabinet M1 cables to PE1, PE2 engines according to the following:
Cable
From end point elect. cab. M1
To end point PE1 or PE2
Notes
CA261-10630
3-phase power supply for PE1 at
JX8
PE1
3 phase 400 VAC power
cable connection. Main AC
power to line filter in PDU
-
CA261-10640
3-phase power supply for PE2 at
JX9
PE2
3 phase 400 VAC power
cable connection. Main AC
power to line filter in PDU
-
6.
Install the electrical cabinet M2 to PE1, PE2 engines according to the following:
Cable
From end point elect. cab. M2
To end point PE1 or PE2
Notes
CA261-10550
Cable from
JX31
Pins L, N, PE
Power cable to
PF1
PDU
-
CA261-10560
Cable from
JX32
Pins L, N, PE
Power cable to
PF2
PDU
-
CC424
Encoder to
WHS green
cable
Electrical cabinet M2
x89
Interface panel
J4
-
CC415
Interlock dark
gray cable
Electrical cabinet M2A
x75
Interface
panel
J3
-
CC426 WH
signal to PE
gray cable
Electrical cabinet M2
x73
Interface
panel
J2
-
CC425 PE
signals to WH
gray cable
Electrical cabinet M2A
x71
Interface
panel
J1
-
CA261-10790
Mains power cable to
PE1 UPS
at
JX31
Connection at
PE1 UPS
Pins
L, N, PE
15F1 control switch
CA261-10800
Main power cable to
PE2 +MC UPS
at
JX32
Connection at
PE2 UPS
Pins
L, N, PE
15F3 control switch
CC73A
Interface panel UPS Com
UPS COM connection
-
W141
Electrical cabinet M2
JX8.1
quick
connector
PDU
-