Cable
From end point elect. cab. M2
To end point PE1 or PE2
Notes
CC236
Electrical cabinet M2
X31.1
– WHS
connector pins PE, 6, 5
PDU
-
CC54A
Slave 1 compartment, Molex
connection in M2A
PDU
-
CC414
Electrical cabinet M2
X61
connector Junction box
-
CC430
Encoder to
WHS green
cable
Electrical cabinet M2 x90
Interface panel J4
-
CC431
Interlock white
cable
Electrical cabinet M2
X76
Interface panel J3
-
CC432 WH
out to PE gray
cable
Electrical cabinet M2
X74
Interface panel J2
-
CC433 PE
signals to
WHS gray
cable
Electrical cabinet M2
X72
Interface panel J1
-
CC74A
UPS Com connection
Interface panel UPS Com
-
W142
Electrical cabinet M2
JX9.1
quick
connector
PDU
-
CC237
Electrical cabinet M2
X32.1
– WHS
connector pins PE, 5, 6
PDU -
CC54A
Slave 2 compartment Molex
connection in electrical cabinet M2
PDU -
CC434
Electrical cabinet M2
X62
connector Junction box
-
7.
Install the electrical cabinet M1-to-master console cables as follows:
Cable
From end point
To end point
Notes
CC77A
RS 232 control for UPS
Master console PC
-
CC27B
UPS power connection for
master console at electrical
cabinet M1
X30
, pins 3,4,5
Master console cabinet,
power-in multiple sockets
-
CC439
Interlock interface to
master (e-stop) electrical
cabinet M1
X54
Master console power
enable switch and
Emergency Stop button
connectors
-
CC68 Communication
between
master computer and PLC
at electrical cabinet M1
53A3
Master console switchbox
connector J6 to plug 6X
-
CC60
Slave 1 Ethernet card in
electrical cabinet M2
Master console two port
Ethernet board
See Figure 107, connect to
right side to modem port No. 1
CC61
Slave 2 Ethernet card in
electrical cabinet M2
Master console two port
Ethernet board
See Figure 107, connect to left
side to modem port No. 1
CC64
Slave 1 switchbox
(electrical cabinet M2 right
side) connector J4 to plug
4X
Master console switchbox
connector J1 to plug
2X
-