Installation Manual
CA294-03070 rev 00
page 67 of 153
c.
Install the PE2-to-Unidrive cables as follows:
Cable
From end point PE2
To end point
CC440
Feed motor
FP2 encoder
26K0
CC441
Feed motor power orange cable
FP2 drive
26K9
pins PE, PE, 2, 4, 6
CC442
Impression engage motor
IP2 encoder
27K0
CC443
Impression engage motor power orange cable
IP2 drive
27K9
pins 2, 4, 6, PE, PE
CC422
Exit nip feed motor
FE encoder
28K0
CC423
Exit nip feed motor power orange cable
FE drive
28K9
pins PE, PE, 2, 4, 6
CC444
Turnbar feed motor
FX encoder
29K0
CC445
Turnbar feed motor power blue cable
FX drive
29K9
pins PE, PE, 2, 4, 6
9.
Install the PE1-to-PE2 cables as follows:
Cable
From end point
To end point
CC9B
Electronic gearing PE2 ESBPRO
J53
connector
PE1 ESBPRO J65 connector
CC114A
PE2 service door interlock
PE1 service door interlock
PE1 ECN Electronic engage cable
PE2 ECN Electronic engage cable
10.
Install the PROFIBUS cables as follows:
Cable
From end point
To end point
Notes
CC428
Purple
Electrical cabinet M2
80A7
connection
Electrical cabinet M1
53A5
connection
Purple cable terminator should be
turned off
Connection is on top of
cable CC408