Installation Manual
CA294-03070 rev 00
page 71 of 153
NOTE:
All vacuum hoses are to be routed appropriately under the
floor platform.
Use metal ring screw clamps to connect all hoses to blowers,
adaptors, and vacuum boxes.
1.
Remove the screws securing the feed panel. Remove the panel and save it and the screws
for later reinstallation.
2.
Connect the four large vacuum hoses to the four blowers in electrical cabinets M1 and M2.
See Figure 50.
Figure 51 Routing vacuum hoses to PE1
PUB_6869
1
1
Four hoses inserted to air ducts at the vacuum box
3.
Route the short ~2m hose connected to the upper blower in electrical cabinet M1 to the
vacuum box in PE1 (Figure 50 and Figure 51).
Use adaptors and small hoses as shown to connect to the vacuum box.