Installation Manual
CA294-03070 rev 00
page 89 of 153
Figure 71 Leveling and aligning the ILP
W3250_ILD_ALIGNMENT_2971
6
5
4
3
2
7
14
15
13
12
11
10
9
8
1
1
ILP external frame
9
Securing nut
2
Feed pull screw (similar at exit)
10
ILP internal frame
3
Feed push screw (similar at exit)
11
ILP frame securing screw
4
ILP internal frame
12
ILP external frame
5
ILP rear foot
13
Position of ILP front frame securing screws
6
ILP feed stepping plate assembly
14
Position of ILP rear frame securing screws
7
ILP front foot
15
ILP exit stepping plate assembly
8
Height adjustment nut
NOTE:
There are two sets of push/pull screws (Figure 71). The
outside screws of each set are the
push
screws. The inside
screws are the
pull
screws. The ILP moves
forward/backward 1 mm for each turn of a screw.
9.
To level and align the ILP (Figure 71):
At the lower ILP frame
a.
Using an Allen M6 key, loosen the six frame securing screws shown in Figure 71.
This allows adjustments to the ILP internal and external frames.