Installation Manual
CA294-03070 rev 00
page 92 of 153
Figure 74 Leveling the ILP at the rollers
1
ILP idler No.3
2 Leveler
3
Roller securing jig
At the ILP feed
f.
Mount the roller securing jig on the idler No.3.
Make sure that the roller is secure. Place the level on the roller.
g.
While one person measures the level at idler No. 3 (Figure 63), another person
should raise/lower the two feet 20 mm height adjustment nuts until the feet rest on the
floor and the ILP is level.
Measure the level to an accuracy of 0.0±0.1 mm.
If necessary, use a jack to raise the frame and place 20 x 20 cm x 2cm spacer plates
under each foot of at the ILP feed.
At the ILP exit
h. Repeat
g above placing a leveler on idler No. 10 (Figure 63).
If necessary, use a jack to raise the frame and place 20 x 20 cm x 2cm spacer plates
under each foot of at the ILP feed.