Installation Manual
CA294-03070 rev 00
page 139 of 153
Configure the press software
Authorization codes
1.
Insert the authorization diskette in the floppy drive.
2. In
the
Options>Authorizations
window, click
Import
3.
Open the A: drive and double-click the
*.aut
file
.
All the present authorization codes in the Authorizations window change color to blue.
4. Click
Apply
.
The authorizations are updated.
Click
Close
.
NOTE:
To manually edit the authorization codes:
1.
Open
the
window
Options
>
Authorization
.
2.
Select and highlight the code line to edit.
3.
Click
Edit
and edit the line.
4.
Click
OK
to accept then
Close
to close the window.
Configuring HP IndigoServe
To configure HP IndigoServe, see HP Indigo Service Instruction
HP IndigoServe 2.0
(P/N CA293-01270).
Configuring Norton anti virus
To configure the anti-virus for daily updates and file scans, see HP Indigo Service Instruction
Norton
anti virus 8.1
(P/N CA293-00660).
Install PIP and blankets
For the PE1 and PE2
Install PIP and blankets to the PIP and IMP drums.
Testing and calibrating the press
Emergency stop tests
1.
Verify that when the master console unit Emergency Stop button is pressed,
all
the following
occur:
At the press MMI and Hunkeler finishing unit touchscreen panels, the touchscreen
panels display that the units are switched to the OFF/ Stopped status.
At electrical cabinet M1, all LEDs of relays 33K0, 33K2, 33K3 33K5 and M1K1 should
be OFF.
NOTE:
When the Emergency Stop button is released, the LEDs of
relay 33K0 are illuminated; all the remaining relays are OFF
and switched ON after the Control On button is pressed on
the unwinder touchscreen panel.
At the Hunkeler finishing unit, relay PNOZ/X1 A5 must be OFF.
2. Release
the
Emergency Stop
button at the master console.