Installation Manual
CA294-03070 rev 00
page 140 of 153
3. Press
the
Emergency Stop
button at the Hunkeler finishing unit, and verify that
all
the
following occur:
At the press MMI and Hunkeler finishing unit touchscreen panels, the touchscreen
panels display that the units are switched to the OFF/ Stopped status.
At electrical cabinet M1, all LEDs of relays 33K0, 33K2 33K3, 33K5 and M1K1 should
be OFF.
NOTE:
When the Emergency Stop button is released, the LEDs of
relay 33K0 are illuminated; all the remaining relays are OFF
and switched ON after the Control On button is pressed on
the unwinder touchscreen panel.
At the Hunkeler finishing unit, both relays PNOZ/X1 A1 and PNOZ/X1 A5 should
switch OFF.
4.
Release the Emergency Stop button at the Hunkeler finishing unit.
Checking the web flow
1.
At the ILP touchscreen, feed the web through the press without priming as follows:
a. Press
Diagnostic
.
b. Press
print simulation
.
c. Press
Print simulation SETUP
.
d. Press
LOGIN
.
e. Press
Password
.
f.
Type in the password using capital letters.
Press
RET
.
g. Press
RET
.
h. Press
print simulation
.
i.
Press the arrow twice.
j. Press
ILP OFF/ON
button until ILP OFF is showing.
k.
Go back to the main screen.
2.
Verify that the web feeds through the press properly.
Checking the ILP priming unit
NOTE:
When adding priming fluid, use 2.5% concentration for
pre-coated substrates. Use 8.5% concentration for uncoated
substrates.
1.
Add ILP fluids as follows:
a.
Pour 1.5 bottles of priming fluid in the left tank.
Make sure the middle sensor float is completely submerged.
b.
Pour 1.5 bottles of water into the right tank.
2.
Make sure the finishing unit(s) is(are) working properly.