Installation Manual
CA294-03070 rev 00
page 144 of 153
The Color Adjustment Wizard Manager window opens.
c. In
the
Automatic Color Adjustment
area, click
Custom Color Adjustment
.
The Custom Color Adjustment wizard opens.
d.
Select the desired matrix.
e. In
the
Electrode Voltage Calibration
field, select
Include Velectrode Calibration
.
f. Click
Next
. The OD step opens.
g. In
the
Select Method of Substrate OD Usage
field, select
Read Substrate OD
.
h. Click
Next
and
.
The color adjustment is performed.
Make sure that the wizard completes all of its steps, and that all colors pass the color
adjust procedure.
i. Click
Finish
.
j.
Load the desired substrate on the press.
k.
Print the CATP job.
l.
In the 9th and 10th copy of the CATP printout, measure the solid patches (J area),
and calculate the average values.
Note the values.
m.
Change the press software to technician mode.
n. From
the
Options
menu, click
Systab Editor
.
The Systab editor window opens.
o. Expand
the
mmiCATopic
tree.
p.
In the right window, double-click
SpecOdLowerDeltaOsm
.
The mmiCATopic SpecOdLowerDeltaOsm window opens.
q. In
the
Saved
field, type
-0.7
.
r. Click
OK
. The window closes.
s. Double-click
SpecOdLowerDelta5
.
The mmiCATopic SpecOdLowerDelta5 window opens.
t. In
the
Saved
field, type
-0.7
.
u. Click
OK
. The window closes.
v.
Close the Systab Editor.
w. From
the
Adjustments
menu, click
Color Adjustment & Calibration
.
The Color Adjustment Wizard Manager window opens.
x. In
the
Automatic Color Adjustment
area, click
Custom Color Adjustment
.
The Custom Color Adjustment wizard opens.
y. In
the
Electrode Voltage Calibration
field, make sure that Include Velectrode
Calibration is not selected.
z. Click
Next
. The OD step opens.
aa. Click
Setup
.
The Setup OD of 100% Spec Values window opens.