Installation Manual
CA294-03070 rev 00
page 145 of 153
bb.
Enter the optical density values noted in step l above in the appropriate color fields.
cc. Click
OK
.
A warning may appear. Click
OK
to close the warning.
dd.
In the wizard, complete the wizard steps.
Make sure that the color calibration is completed successfully.
ee. From
the
Diagnostics
menu, click
Writing Head
.
The Writing Head window opens.
ff. Click
the
Laser Power
tab.
gg.
Check that the Laser Power values do not approach the upper or lower limits (30 to
1).
If the values are at either extremity, perform the Machine LUT Calibration wizard from
Adjustments
>
Machine LUT Calibration
.
11.
If necessary, perform the Machine LUT using 180 lpi.
Testing during normal operation
Perform normal printing for a period of four hours per day without using the bypass key. If no errors
occur, proceed to the next procedure.
Check the printout for any print defects.
Diagnose and correct any printing problems that occur during this period. If errors occur, locate and
correct the errors.
Customer acceptance test procedure (CATP)
Introduction to CATP
The CATP job is a tool to be used by CEs and as part of the ATP during integration.
This job enables the testing and verification of the performance of the press after any of the following
situations:
•
Press installation (after completion of installation, COI, to demonstrate press performance
to the customer)
•
Service call (per normal CE repair routine)
•
Periodic maintenance (per normal CE maintenance routine)
It contains elements that allow the verification of a wide range of press parameters.
More information about CATP
•
A reference master CATP test print is included with each press. Use it as the reference
print to compare the periodic CATP print results.
•
The job is printed in HDI 180 screen using Chromalin mode.
•
The job can be divided into three main test groups:
•
Image
Spec.
•
Color
Spec.
•
Quality
Check