ENWW
ITM temperature sensor 127
ITM temperature sensor
The infrared (IR) temperature sensor reads the ITM drum temperatures. The temperature
sensor readings are used to turn the ITM heating on and off to keep the blanket at a
pre-set temperature.
Clean the ITM shoulder below the IR temperature sensor using a lint-free wipe soaked
with imaging oil.
Before carrying out this procedure, make sure to have the following items:
z
lint-free wipes
z
imaging oil
Perform the procedure only when the ITM drum has cooled to room temperature. Perform
the following procedure weekly:
1
On the control panel, click
Standby
. The press changes to the Standby state.
2
Open the upper feed door.
3
Lift the ITM hood.
4
Using lint-free wipes soaked in IPA, clean the ITM area that comes into contact with
the ITM thermal fuse. Use a blunt, plastic knife to scrape off the dry ink.
5
Using the inch-safe-service method (see ‘Inch-safe-service method’ on page 32),
rotate the drum. Clean the complete drum circumference.
6
Wipe the blanket dry.
7
Close the ITM hood.
8
Close all doors.
Figure 9-19. ITM IR temperature sensor
Infrared temperature
sensor
Clean below guard
Summary of Contents for Indigo press 3050
Page 1: ...HP Indigo press 3050 User guide English version ...
Page 2: ...hp indigo press 3050 user guide ...
Page 13: ...12 Chapter 1 Preface ENWW ...
Page 23: ...22 Chapter 2 Getting started ENWW ...
Page 41: ...40 Chapter 4 HP Indigo press 3050 basics ENWW Figure 4 5 Related topics ...
Page 53: ...52 Chapter 5 The main windows ENWW ...
Page 83: ...82 Chapter 6 Operating the press ENWW ...
Page 91: ...90 Chapter 7 Operator routines ENWW Figure 7 7 Inner front wall O O O O ...
Page 99: ...98 Chapter 7 Operator routines ENWW ...
Page 136: ...ENWW 135 10PIP This chapter contains the following sections z Overview z Replacing the PIP ...
Page 189: ...188 Chapter 11 Paper transport ENWW ...
Page 219: ...218 Chapter 15 Scorotron ENWW ...
Page 257: ...256 Chapter 17 Pre transfer erase PTE ENWW ...
Page 271: ...270 Chapter 19 Chiller ENWW ...