ENWW
Scorotron maintenance procedures 213
Replacing the scorotron corona
Replace the scorotron corona when you clean or replace the corona wire and the corona
grids in the scorotron unit. When replacing the corona wire, also replace the scorotron
damper.
Note
The corona wire is advanced automatically to expose new wire after 4500 to 6000 impressions.
Before performing this procedure, make sure you have the following items:
z
Corona bobbin with wire
z
Empty PVC bobbin
z
Two corona grids
z
Scorotron dumpers
z
Phillips screwdriver
Use the following procedure to replace the scorotron corona:
1
Open the front door.
2
Remove the scorotron unit by pressing the scorotron latch and pulling the unit out.
Place the unit on the worktable.
Figure 15-2. Scorotron unit
Scorotron latch
Summary of Contents for Indigo press 3050
Page 1: ...HP Indigo press 3050 User guide English version ...
Page 2: ...hp indigo press 3050 user guide ...
Page 13: ...12 Chapter 1 Preface ENWW ...
Page 23: ...22 Chapter 2 Getting started ENWW ...
Page 41: ...40 Chapter 4 HP Indigo press 3050 basics ENWW Figure 4 5 Related topics ...
Page 53: ...52 Chapter 5 The main windows ENWW ...
Page 83: ...82 Chapter 6 Operating the press ENWW ...
Page 91: ...90 Chapter 7 Operator routines ENWW Figure 7 7 Inner front wall O O O O ...
Page 99: ...98 Chapter 7 Operator routines ENWW ...
Page 136: ...ENWW 135 10PIP This chapter contains the following sections z Overview z Replacing the PIP ...
Page 189: ...188 Chapter 11 Paper transport ENWW ...
Page 219: ...218 Chapter 15 Scorotron ENWW ...
Page 257: ...256 Chapter 17 Pre transfer erase PTE ENWW ...
Page 271: ...270 Chapter 19 Chiller ENWW ...