ENWW
Replacing the BID 221
Replacing the BID
Replace the BID station when the following occurs:
z
image quality deteriorates
z
change of ink color is required
Before you start this procedure, make sure that you have the following items:
z
A new BID
z
BID stand
z
3-mm Allen key
z
Lint-free wipe
z
Imaging oil
Diagnostics
The BID Diagnostic Wizard is used to diagnose BID problems off-line. BID diagnostics
should be performed before removing a suspect BID from the press. Use this wizard to
check BID units for correct flow rate, proper mechanical movement (Positive Developer
Not Rotating), correct BID biases, and for open and short circuits.
The BID wizard is automatic, and will either indicate that the BID is okay, or show a
specific error message.
To perform BID diagnostics, perform the following:
1
On the control panel, click
Standby
.
2
From the Control Panel, click
Diagnostics
and
BID Diagnostics
. The
BID Diagnostic
Wizard
opens.
3
Select the BID units to be tested, and click
Next
.
Figure 16-2.
BID
Diagnostic Wizard
–
BIDs Selection
window
Summary of Contents for Indigo press 3050
Page 1: ...HP Indigo press 3050 User guide English version ...
Page 2: ...hp indigo press 3050 user guide ...
Page 13: ...12 Chapter 1 Preface ENWW ...
Page 23: ...22 Chapter 2 Getting started ENWW ...
Page 41: ...40 Chapter 4 HP Indigo press 3050 basics ENWW Figure 4 5 Related topics ...
Page 53: ...52 Chapter 5 The main windows ENWW ...
Page 83: ...82 Chapter 6 Operating the press ENWW ...
Page 91: ...90 Chapter 7 Operator routines ENWW Figure 7 7 Inner front wall O O O O ...
Page 99: ...98 Chapter 7 Operator routines ENWW ...
Page 136: ...ENWW 135 10PIP This chapter contains the following sections z Overview z Replacing the PIP ...
Page 189: ...188 Chapter 11 Paper transport ENWW ...
Page 219: ...218 Chapter 15 Scorotron ENWW ...
Page 257: ...256 Chapter 17 Pre transfer erase PTE ENWW ...
Page 271: ...270 Chapter 19 Chiller ENWW ...