EN
Using the touch screen 7
Viewing the alarms and messages
Alarms and messages can appear at the bottom of the Operator screen. Follow the
instructions in table 1-2.
Table 1-2. Alarms and messages
Alarm / message
Instructions
Factory default values set. Please calibrate
dancer
Calibrate the dancer.
Local emergency stop activated
Release the rewinder emergency stop button.
Motor failure
Turn off the rewinder. Wait two minutes. Turn on
the rewinder. If the problem continues, contact
technical support.
PE cover open
Close the cover.
Picking up web. Please wait
Wait until the rewinder finishes picking up the
web.
Press “PE Print” / “PE Feed” to activate
print/feed cycle
Touch PE Print or PE Feed.
Printing engine is not ready
Put the printing engine into ready mode.
Remote emergency stop activated
Release the emergency stop button.
Rewinder can’t start when clamps are down.
Release clamps
Touch the right and left Up Clamp buttons.
Rewinder is not ready
Touch Standby On/Off.
Roll has reached maximum size
Remove the roll. Insert a new core.
Touch panel communication trouble
Turn off the rewinder. Wait two minutes. Turn on
the rewinder. If the problem continues, contact
technical support.
Web break
Fix the broken web or raise the dancer arm from
the lowest position.