Chapter 1
19
Product Information
Front Panel Components
The Hot-Plug Procedure
These are the steps required to properly hot-plug a disk drive:
Step 1
• Check if the LVM found the physical volume to be defective when the volume group was
activated.
• The
“vgchange
-a
y”
command would have printed the following message on the
console:
WARNING:
VGCHANGE:WARNING: COULDN’T ATTACH TP THE VOLUME GROUP
PHYSICAL VOLUME “/DEV/DSK/cXtXdX”
THE PATH OF THE PHYSICAL VOLUME REFERS TO A DEVICE THAT DOES NOT
EXIST, OR IS NOT CONFIGURED INTO THE KERNEL.
• If the status of the “
vgchange -v vg02
” is unknown, you may check if this occurred by
doing a vgdisplay command:
vgdisplay<
VG name>
For our example:
vgdisplay /dev/vg00
• If the disk was defective at vgchange time, the following messages
will be printed one or more times:
WARNING:
VGDISPLAY: WARNING: COULDN’T QUERY PHYSICAL VOLUME
“/DEV/DSK/cXtXdX”
THE SPECIFIED PATH DOES NOT CORRESPOND TO PHYSICAL VOLUME
ATTACHED TO THE VOLUME GROUP.
VGDISPLAY: WARNING: COULDN’T QUERY ALL OF THE PHYSICAL
VOLUMES
• If you see these messages, the disk was defective at the time the volume group was
activated.
Otherwise, your disk became defective after the
vgchange
and you must continue with
step 2 of this procedure.
Summary of Contents for j6700
Page 1: ...Service Handbook HP VISUALIZE J6700 Workstations Manufacturing Part Number n a Edition E0501 ...
Page 8: ...8 Contents ...
Page 30: ...30 Chapter1 Product Information Monitors ...
Page 76: ...76 Chapter3 Troubleshooting Using the System Board LEDs for Troubleshooting ...
Page 100: ...100 Chapter4 Field Replaceable Units FRUs FRU Removal and Replacement ...
Page 134: ...134 Chapter5 Boot Console Handler Initial System Loader ISL Environment ...
Page 150: ...150 Appendix B SCSI Connections How To Connect An SE SCSI Device ...