2-12
Installing the Switch
Installation Procedures
Wall or Under-Table Mounting
You can mount the switch on a wall or under a table. A special kit for wall and
under-table mounting is included with the switch.
W A R N I N G
For safe operation, do not mount any of the switches with side
ventilation ducts facing up or down.
Wall-mount the switches with network ports facing up (away from the
floor) or down (toward the floor).
C a u t i o n
The switch should be mounted only to a wall or wood surface that is at least
1/2-inch (12.7 mm) plywood or its equivalent.
1.
In the required location, mark the position for the mounting screws. For
the V1410-8 Switch, the hole-to-hole distance is 3.54 inch (90.0 mm). For
the V1410-16 Switch, V1410-24 Switch, and V1410-24-2G Switch, the hole-
to-hole distance is 5.91 inch (150.0 mm).
2.
Use a #1 Phillips (cross-head) screwdriver and two of the included 20-mm
M4 tap screws to mount the switch on the wall or wood surface.
Wall anchors are included in the accessory kit for use with plastered brick
or concrete walls.
Figure 2-7. Wall mounting the switch
Wall
20-mm M4
tap screws
RJ-45 Ports
Wall anchors