30
Installing the enclosures
Connect power cable to DC power supply
Locate two DC power cables that are compatible with your controller enclosure.
Figure 18
DC power cable featuring sectioned D-shell and lug connectors
and the illustration at left (in
) when performing the following steps:
1.
Verify that the enclosure power switches are in the
Off
position.
2.
Connect a DC power cable to each DC power supply using the D-shell connector.
Use the
UP>
arrow on the connector shell to ensure proper positioning (see adjacent
left side view of D-shell connector).
3.
Tighten the screws at the top and bottom of the shell, applying a torque between 1.7
N-m (15 in-lb) and 2.3 N-m (20 in-lb), to securely attach the cable to the DC power
supply module.
4.
To complete the DC connection, secure the other end of each cable wire component
of the DC power cable to the target DC power source.
Check the three individual DC cable wire labels before connecting each cable wire lug to its power
source. One cable wire is labeled
ground
(GND) and the other two wires are labeled
positive
(+L) and
negative
(-L), respectively (shown in
above).
CAUTION:
Connecting to a DC power source outside the designated -48V DC nominal range
(-36V DC to -72V DC) may damage the enclosure.
Connect power cord to legacy AC power supply
Obtain two suitable AC power cords: one for each AC power supply that will connect to a separate power
source. See the illustration at right [in
(page 29)] when performing the following steps:
1.
Verify that the enclosure power switches are in the
Off
position.
2.
Identify the power cord connector on the power supply, and locate the target power source.
3.
For each power supply, perform the following actions:
a.
Plug one end of the cord into the power cord connector on the power supply.
b.
Plug the other end of the power cord into the rack power source.
4.
Verify connection of primary power cords from the rack to separate external power sources.
Power cycle
To power on the system:
1.
Power up drive enclosure(s).
Press the power switches at the back of each drive enclosure to the
On
position. Allow several seconds
for the disks to spin up.
2.
Power up the controller enclosure next.
Press the power switches at the back of the controller enclosure to the
On
position. Allow several
seconds for the disks to spin up.
To power off the system:
1.
Stop all I/O from hosts to the system [see
2.
Shut down both controllers using either method described below:
+L
GND
-L
+L
GND
-L
+L
GND
-L
+L
GND
-L
Connector pins (typical 2 places)
Connector (front view)
Ring/lug connector (typical 3 places)
D-shell
(left side view)
Summary of Contents for MSA 2040
Page 8: ...8 Figures ...
Page 10: ...10 Tables ...
Page 32: ...32 Installing the enclosures ...
Page 44: ...44 Connecting hosts ...
Page 50: ...50 Connecting to the controller CLI port ...
Page 52: ...52 Basic operation ...
Page 70: ...70 Troubleshooting ...
Page 74: ...74 Support and other resources ...
Page 76: ...76 Documentation feedback ...
Page 88: ...88 LED descriptions ...
Page 94: ...94 Electrostatic discharge ...
Page 100: ...100 Index ...