Rear panel LEDs
85
MSA 2040 SAS controller module—rear panel LEDs
1
See the qualified HD mini-SAS host cable options described in the QuickSpecs.
2
When port is down, both LEDs are off.
Figure 37
LEDs: MSA 2040 SAS controller module
NOTE:
Once a Link Status LED is lit, it remains so, even if the controller is shutdown via the SMU or CLI.
LED
Description
Definition
1
Host 6/12 Gb SAS,
1
Link Status
Off — No link detected.
Green — The port is connected and the link is up.
2
Host 6/12 Gb SAS
1
Link Activity
Off — The link is idle.
Blinking green — The link has I/O activity.
3
Network Port Link
Active Status
2
Off — The Ethernet link is not established, or the link is down.
Green — The Ethernet link is up (applies to all negotiated link speeds).
4
Network Port Link Speed
2
Off — Link is up at 10/100base-T negotiated speeds.
Amber — Link is up and negotiated at 1000base-T.
5
OK to Remove
Off — The controller module is not prepared for removal.
Blue — The controller module is prepared for removal.
6
Unit Locator
Off — Normal operation.
Blinking white — Physically identifies the controller module.
7
FRU OK
Off — Controller module is not OK.
Blinking green — System is booting.
Green — Controller module is operating normally.
8
Fault/Service Required
Amber — A fault has been detected or a service action is required.
Blinking amber — Hardware-controlled power-up or a cache flush or restore
error.
9
Cache Status
Green — Cache contains unwritten data and operation is normal. The
unwritten information can be log or debug data that remains in the cache, so
a Green cache status LED does not, by itself, indicate that any user data is at
risk or that any action is necessary.
Off — In a working controller, cache is clean (contains no unwritten data).
This is an occasional condition that occurs while the system is booting.
Blinking green — A CompactFlash flush or cache self-refresh is in progress,
indicating cache activity.
See also
10
Expansion Port Status
Off — The port is empty or the link is down.
On — The port is connected and the link is up.
CACHE
CLI
CLI
LINK
ACT
6Gb/s
SERVICE−1
SERVICE−2
ACT
LINK
12Gb/s
S
S
A
ACT
LINK
SAS 1 SAS 2
ACT
LINK
12Gb/s
S
S
A
ACT
LINK
SAS 3 SAS 4
5
3
4
6
1
8 9
7
:
2
Summary of Contents for MSA 2040
Page 8: ...8 Figures ...
Page 10: ...10 Tables ...
Page 32: ...32 Installing the enclosures ...
Page 44: ...44 Connecting hosts ...
Page 50: ...50 Connecting to the controller CLI port ...
Page 52: ...52 Basic operation ...
Page 70: ...70 Troubleshooting ...
Page 74: ...74 Support and other resources ...
Page 76: ...76 Documentation feedback ...
Page 88: ...88 LED descriptions ...
Page 94: ...94 Electrostatic discharge ...
Page 100: ...100 Index ...