Tools and Utilities
7-23
Installation Verification Procedure (IVP)
The Installation Verification Procedure runs automatically each time an IOP boots. It evaluates
the server’s Ethernet bindings and reports its findings to the event log on the local IOP.
You can also run the installation verification procedure manually whenever you want to re-
evaluate the Ethernet bindings. To run the procedure, open an MS-DOS command window and
type
mtcivp
. The results are written to the event log on the IOP from which you run the
procedure. To view the data on the screen as well as in the event logs, use the verbose form of
the command. To do so, type
mtcivp
/verbose
.
The messages about these findings constitute a new class of Endurance messages, the IVP
messages. These unprefixed messages are described in
Chapter 3
in
HP Netserver AA Solution
Messages
.