8. Coat the new/cleaned wiper blade with your preferred
lubricant. Install the wiper blade and two screws.
9. Install the cleaned PCR. Place a small amount of conductive
grease on to the black holder side of the shaft. Just a small
amount of grease is more than sufficient.
10. Place another small amount of conductive grease on to
the metal drum axle.
11. Install the new/cleaned drum hub side first.
Place the waste/drum section aside.
UNINET IMAGING INC.
•