114 Alphabetical list of commands
rescan
Description
This command forces rediscovery of disks and enclosures in the storage system. If both Storage
Controllers are online and able to communicate with both expansion modules in each connected
enclosure, this command rebuilds the internal SAS layout information, reassigns enclosure IDs based
on controller A’s enclosure cabling order, and ensures that the enclosures are displayed in the proper
order. A manual rescan temporarily pauses all I/O processes, then resumes normal operation. It can
take up to two minutes for the enclosure IDs to be corrected.
A manual rescan may be needed after system power-up to display enclosures in the proper order.
Whenever you replace a drive chassis or controller chassis, perform a manual rescan to force fresh
discovery of all drive enclosures connected to the controller enclosure.
A manual rescan is not needed after inserting or removing disks; the controllers automatically detect
these changes. When disks are inserted they are detected after a short delay, which allows the disks
to spin up
Syntax
rescan
Example
Scan for device changes and re-evaluate enclosure IDs:
# rescan
Success: Command completed successfully. (2012-01-21 12:20:57)
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...