HP P2000 G3 MSA System CLI Reference Guide 151
set expander-fault-isolation
Description For use by or with direction from a service technician.
By default, the Expander Controller in each I/O module performs fault-isolation analysis of SAS
expander PHY statistics. When one or more error counters for a specific PHY exceed the built-in
thresholds, the PHY is disabled to maintain storage system operation.
While troubleshooting a storage system problem, a service technician can use this command to
temporarily disable fault isolation for a specific Expander Controller in a specific enclosure.
NOTE:
If fault isolation is disabled, be sure to re-enable it before placing the system back into
service. Serious problems can result if fault isolation is disabled and a PHY failure occurs.
Syntax
set expander-fault-isolation
encl
enclosure-ID
controller a|b|both
enabled|disabled|on|off
Parameters
encl
enclosure-ID
The enclosure ID of the enclosure containing the PHY.
controller a|b|both
The I/O module containing the Expander Controller whose setting you want to change: A, B, or
both.
enabled|disabled|on|off
Whether to enable or disable PHY fault isolation.
Example
Disable PHY fault isolation for Expander Controller A in an enclosure:
# set expander-fault-isolation encl 1 controller a disabled
Success: Command completed successfully. - Expander fault isolation was
disabled. (2012-01-21 12:05:41)
Re-enable PHY fault isolation for Expander Controller A in the same enclosure:
# set expander-fault-isolation encl 1 controller a enabled
Success: Command completed successfully. - Expander fault isolation was enabled.
(2012-01-21 12:05:51)
See also
•
set expander-phy
•
show enclosures
•
show expander-status
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...