224 Alphabetical list of commands
show enclosures
Description
Shows information about the enclosures in the storage system. Full detail available in XML API output
only.
Syntax
show enclosures
Output
Encl
Enclosure ID.
Encl WWN
Enclosure WWN.
Name
Enclosure name.
Location
Enclosure location; blank if not set.
Rack
Number of the rack containing the enclosure.
Pos
Position of the enclosure in the rack.
Vendor
Enclosure vendor.
Model
Enclosure model.
EMP
#
BUS:ID Rev
Address and firmware revision of the Enclosure Management Processor in each controller’s
Expander Controller.
Midplane Type
•
2U24-6Gv2
: Midplane for 2U, reduced-depth, 24-disk enclosure with 6-Gbps maximum data
rate to disks.
•
2U24-6G
: Midplane for 2U, 24-disk enclosure with 6-Gbps maximum data rate to disks.
•
2U24-3G
: Midplane for 2U, 24-disk enclosure with 3-Gbps maximum data rate to disks.
•
2U12-6Gv2
: Midplane for 2U, reduced-depth, 12-disk enclosure with 6-Gbps maximum data
rate to disks.
•
2U12-6G
: Midplane for 2U, 12-disk enclosure with 6-Gbps maximum data rate to disks.
•
2U12-3G
: Midplane for 2U, 12-disk enclosure with 3-Gbps maximum data rate to disks.
•
N/A
: Other type of midplane.
Health
•
OK
•
Degraded
•
Fault
•
Unknown
Health Reason
If Health is not
OK
, this field shows the reason for the health state.
Health Recommendation
If Health is not
OK
, this field shows recommended actions to take to resolve the health issue.
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...