HP P2000 G3 MSA System CLI Reference Guide 231
show expander-status
Description For use by or with direction from a service technician.
Shows diagnostic information relating to SAS Expander Controller physical channels, known as PHY
lanes. For each enclosure, this command shows status information for PHYs in I/O module A and
then I/O module B.
Syntax
show expander-status
Output
Encl
Enclosure that contains the SAS expander.
Ctlr
I/O module that contains the SAS expander.
Phy
Identifies a PHY’s logical location within a group based on the PHY type. Logical IDs are 0–23 for
drive PHYs; 0–1 for SC PHYs; and 0–3 for other PHYs. If the PHY's controller module or expansion
module is not installed, this field shows “
--
”.
Type
•
Drive
: 1-lane PHY that communicates between the expander and a disk drive.
•
Egress
: 4-lane PHY that communicates between the expander and an expansion port or SAS
Out port.
•
SC-1
: (Controller module only) 2-lane PHY that communicates between the expander and the
partner’s expander.
•
SC-0
: (Controller module only) 4-lane PHY that communicates between the expander and the
SC.
•
Ingress
: (Expansion module only) 4-lane PHY that communicates between the expander and
an expansion port.
•
Inter-Exp
: (Expansion module only) Communicates between the expander and the partner’s
expander.
•
Undefined
: No status information is available.
•
Unused
:
The PHY exists in the expander but is not connected, by design
.
Status
•
Enabled - Healthy
: The PHY is enabled and healthy.
•
Enabled - Degraded
: The PHY is enabled but degraded.
•
Disabled
: The PHY has been disabled by a user or by the system.
Elem Status
A standard SES status for the element:
•
Disabled
: Critical condition is detected.
•
Error
: Unrecoverable condition is detected. Appears only if there is a firmware problem related
to PHY definition data.
•
Non-critical
: Non-critical condition is detected.
•
Not Used
: Element is not installed in enclosure.
•
OK
: Element is installed and no error conditions are known.
•
Unknown
: Either:
• Sensor has failed or element status is not available. Appears only if an I/O module indicates
it has fewer PHYs than the reporting I/O module, in which case all additional PHYs are
reported as unknown.
• Element is installed with no known errors, but the element has not been turned on or set into
operation.
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...