HP P2000 G3 MSA System CLI Reference Guide 357
cache-settings
Properties
Example
# show cache-parameters vd02_v001
...
<OBJECT basetype="cache-settings" name="system-cache-parameters" oid="1"
format="pairs">
<PROPERTY name="operation-mode" type="string">Active-Active ULP</PROPERTY>
<PROPERTY name="operation-mode-numeric" type="string">2</PROPERTY>
</OBJECT>
...
Embedded basetypes
•
controller-cache-parameters
Table 13
cache-settings properties
Name
Type
Description
operation-mode
string
The system’s operating mode, also called the cache redundancy mode.
•
Active-Active ULP
: Both controllers are active using ULP (Unified LUN
Presentation). Data for volumes configured to use write-back cache is
automatically mirrored between the two controllers to provide fault
tolerance.
•
Single Controller
: There is only a single controller in the enclosure.
•
Fail Over
: Operation has failed over to one controller because its partner
is not operational. The system has lost redundancy.
•
Down
: Both controllers are not operational.
operation-mode-
numeric
string
Numeric equivalents for
operation-mode
values.
•
2: Active-Active ULP
•
3: Single Controller
•
4: Fail Over
•
5: Down
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...