HP P2000 G3 MSA System CLI Reference Guide 373
Example
# show controller-statistics
...
<OBJECT basetype="controller-statistics" name="controller-statistics" oid="1"
format="rows">
<PROPERTY name="durable-id" type="string">controller_A</PROPERTY>
<PROPERTY name="cpu-load" type="uint32">6</PROPERTY>
<PROPERTY name="power-on-time" type="uint32">171975</PROPERTY>
<PROPERTY name="write-cache-used" type="uint32">0</PROPERTY>
<PROPERTY name="bytes-per-second" units="KB" type="string">667.64KB</PROPERTY>
<PROPERTY name="bytes-per-second-numeric" type="string">667648</PROPERTY>
<PROPERTY name="iops" type="uint32">2</PROPERTY>
<PROPERTY name="number-of-reads" type="uint64">386768</PROPERTY>
<PROPERTY name="read-cache-hits" type="uint64">10192</PROPERTY>
<PROPERTY name="read-cache-misses" type="uint64">6097968</PROPERTY>
<PROPERTY name="number-of-writes" type="uint64">98020</PROPERTY>
<PROPERTY name="write-cache-hits" type="uint64">83360</PROPERTY>
<PROPERTY name="write-cache-misses" type="uint64">728185</PROPERTY>
<PROPERTY name="data-read" units="GB" type="string">100.01GB</PROPERTY>
<PROPERTY name="data-read-numeric" type="string">100017762304</PROPERTY>
<PROPERTY name="data-written" units="GB" type="string">11.80GB</PROPERTY>
<PROPERTY name="data-written-numeric" type="string">11807576064</PROPERTY>
<PROPERTY name="reset-time" type="string">2012-02-13 12:45:35</PROPERTY>
<PROPERTY name="reset-time-numeric" type="string">1329137135</PROPERTY>
<PROPERTY name="start-sample-time" type="string">2012-02-24 12:47:34</PROPERTY>
<PROPERTY name="start-sample-time-numeric" type="string">1330087654</PROPERTY>
<PROPERTY name="stop-sample-time" type="string">2012-02-29 10:19:57</PROPERTY>
<PROPERTY name="stop-sample-time-numeric" type="string">1330510797</PROPERTY>
<PROPERTY name="total-power-on-hours" type="string">911.48</PROPERTY>
</OBJECT>
...
start-sample-
time-numeric
string
Unformatted
start-sample-time
value.
stop-sample-
time
string
Date and time, in the format
year-month-day hour
:
minutes
:
seconds
,
when sampling stopped for the
iops
and
bytes-per-second
values.
stop-sample-
time-numeric
string
Unformatted
stop-sample-time
value.
total-power-on-
hours
string
The total amount of hours the controller has been powered on in its life time.
Table 20
controller-statistics properties (continued)
Name
Type
Description
Summary of Contents for P2000 G3
Page 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Page 14: ...14 About this guide ...
Page 30: ...30 Categorical list of commands ...
Page 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Page 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Page 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Page 524: ...524 Glossary ...
Page 532: ...532 Index ...