Appendix A
Event Codes
Pager
Code
Server Event
Severity
002XX
Voltage sensor crossed lower non-recoverable threshold
CRITICAL
002XX
A measured voltage in the server has gone outside the factory
specified upper voltage range.
WARNING
002XX
A measured voltage in the server has gone far outside the factory
specified upper voltage range.
CRITICAL
002XX
Voltage sensor crossed upper non-recoverable threshold
CRITICAL
002XX
System Voltage failure
WARNING
00432
A system fan module error has occurred
WARNING
00432
A system fan module error has occurred
CRITICAL
00432
Fan module failure
WARNING
00432
Fan module failure
CRITICAL
004XX
A fan sensor in the server has gone outside the factory specified
range.
WARNING
004XX
A fan sensor in the server has gone far outside the factory specified
range.
CRITICAL
004XX
Fan sensor crossed lower non-recoverable threshold
CRITICAL
004XX
Fan sensor crossed upper non-critical threshold
WARNING
004XX
Fan sensor crossed upper critical threshold
CRITICAL
004XX
Fan sensor crossed upper non-recoverable threshold
CRITICAL
004XX
Two or more of the fans in the Processor/PCI Fan Tray have stopped
or have been removed.
CRITICAL
004XX
Fan problem in Processor/PCI Fan Tray has been corrected.
INFORMATIONAL
004XX
Two or more of the fans in the Memory Fan Tray have stopped or
been removed.
CRITICAL
004XX
Fan problem in the Memory Fan Tray has been corrected.
INFORMATIONAL
004XX
One of the fans in the Memory Fan Tray stopped.
CRITICAL
004XX
One of the fans in the Processor/PCI fan tray stopped.
CRITICAL
00520
I/O area open
WARNING
00530
The server's built-in sensors have detected an open chassis door.
WARNING
00530
Processor area open
WARNING
00600
Front Panel Button Violation INFORMATIONAL
00700
Processor internal error
CRITICAL
00701
Processor module is operating outside of acceptable margins
WARNING
00701
Processor Thermal Trip Failure
CRITICAL
00702
Processor failed internal self test
CRITICAL
00703
Processor hung during POST
CRITICAL
00704
Processor startup/initialization failed
CRITICAL