Appendix A
Event Codes
Pager
Code
Server Event
Severity
21114
SCSI: Device has been recovered
NORMAL
21115
SCSI: Device has changed
INFORMATIONAL
21116
SCSI: Predictive failure condition detected
CRITICAL
21117
SCSI: ASPI database has been cleared
INFORMATIONAL
21118
SCSI: ASPI interface has crashed
CRITICAL
21119
SCSI: Insufficient memory for ASPI operation
WARNING
21120
SCSI: Unable to open ASPI file for writing
WARNING
21121
SCSI: Unable to open ASPI file
WARNING
21122
SCSI: ASPI device file does not exist
WARNING
21123
SCSI: Memory allocation is failing
WARNING
21124
SCSI: Unable to read the database file
WARNING
21125
SCSI: Database is corrupted
WARNING
21126
SCSI: ASPI model initializing
INFORMATIONAL
21130
Scsiflt/SMART: SNMP agent being unloaded or stopped INFORMATIONAL
21131
SCSIFLT/SMART: SNMP agent is functioning
INFORMATIONAL
21138
A new host adapter has been discovered
INFORMATIONAL
21139
An installed host adapter no longer matches the information stored
about it.
INFORMATIONAL
21140
An installed host adapter can no longer be deteced.
CRITICAL
21141
A host adapter that previously failed is now accessible.
NORMAL
21142
An installed SCSI device can no longer be detected.
CRITICAL
21143
A new SCSI device, such as CD-ROM drive, hard drive or tape
drive, has been detected.
INFORMATIONAL
21144
An installed SCSI drive that previously failed is now accessible.
NORMAL
21145
SCSI: Device has changed
INFORMATIONAL
21146
SCSI: Predictive failure condition detected
CRITICAL
21147
ScsiSMART: Internal error
INFORMATIONAL
21201
NetRAID: Configuration updated
INFORMATIONAL
21202
NetRAID: Change in state of physical drive
WARNING
21203
NetRAID: Change in state of logical drive
WARNING
21204
NetRAID: Logical drive initialization Started
INFORMATIONAL
21205
NetRAID: Logical drive initialization completed
INFORMATIONAL
21206
NetRAID: Logical drive initialization aborted
WARNING
21207
NetRAID: Logical drive initialization failed
CRITICAL
21208
NetRAID: Logical drive consistency check operation started
INFORMATIONAL
21209
NetRAID: Logical drive consistency check operation completed
INFORMATIONAL
62