Appendix A
A-35
HP-UX UPS Monitor Error Messages
Log-Only Messages
MESSAGE
ups_mond: UPS <tty special file name> Current Overload -
either UPS bad or too many devices connected
SEVERITY
Warning. PowerTrust hardware has not failed, but has a condition that puts
the system in jeopardy of going down if the condition is not corrected.
MEANING
The PowerTrust device configured as <tty special file name> informed the UPS
Monitor that it detected an abnormally high demand for output power from its
AC outlet (approximately 100% of allowable output power). The PowerTrust
unit is still operational, but if the power demand goes higher, the overload
could increase to a level that causes the PowerTrust unit to turn itself off (refer
to the
Current Overload; UPS turned itself off
message in the
reboot(2) Messages section of this appendix).
CAUSE
Improper system hardware installation has put too much load on the
PowerTrust unit, or a hardware malfunction in the system equipment being
powered by the PowerTrust unit has increased the power demand to the point
of overload.
ACTION
Call HP Service.
MESSAGE
ups_mond: UPS <tty special file name> High Ambient
Temperature - reduce area temperature
SEVERITY
Warning. PowerTrust hardware has not failed, but has a condition that puts
the system in jeopardy of going down if the condition is not corrected.
MEANING
The PowerTrust device configured as <tty special file name> informed the UPS
Monitor that it detected an abnormally high ambient temperature, indicating
insufficient cooling of the equipment area. The PowerTrust unit is still
operational, but could progress to a High Ambient Temperature condition if
the room temperature goes higher.
CAUSE
The temperature in the computer room is getting too hot.
ACTION
Reduce the temperature in the computer room.
Summary of Contents for PowerTrust A3589A
Page 7: ...Contents Contents 5 ...
Page 8: ...Contents 6 Contents ...
Page 10: ...Contents 8 Figures ...
Page 12: ...Contents 10 Tables ...
Page 14: ...2 ...
Page 20: ...Preface 8 ...
Page 22: ...Preface 10 ...
Page 52: ...1 30 Chapter1 Overview Specifications Figure 1 8 UPS Input Voltage Transfer Points ...
Page 56: ...1 34 Chapter1 Overview UPS Modes Figure 1 10 Simplified UPS 5 5 kVA UPS Block Diagram ...
Page 62: ...1 40 Chapter1 Overview Support Information ...
Page 76: ...2 14 Chapter2 Unpacking and Inspecting Shipping and Storage Requirements ...
Page 104: ...3 28 Chapter3 Installing the UPS Examples of PowerTrust Connections in a System ...
Page 116: ...5 4 Chapter5 Verification Procedures Load Testing ...
Page 148: ...7 6 Chapter7 Cleaning and Maintenance Exchanging Batteries Fan ...
Page 190: ...A 42 AppendixA HP UX UPS Monitor Error Messages Log Only Messages ...
Page 218: ...C 8 AppendixC Configuring the OS for the PowerTrust UPS Power Failing the UPS ...