C-36
Troubleshooting
Restoring a Flash Image
4.
Since the OS file is larage, you can increase the speed of the download by
changing the switch console and terminal emulator baud rates to a high
speed. For example:
a.
Change the switch baud rate to 115,200 Bps.
=> sp 115200
b.
Change the terminal emulator baud rate to match the switch speed:
i.
In HyperTerminal, select
Call
|
Disconnect
.
ii.
Select
File
|
Properties
.
iii. click on
[Configure . . .]
.
iv. Change the baud rate to
115200
.
v.
Click on
[OK]
. In the next window, click on
[OK]
again.
vi. Select
Call
|
Connect
vii. Press
[Enter]
one or more times to display the => prompt.
5.
Start the Console Download utility by typing
do
at the
=>
prompt and
pressing
[Enter]
:
=> do
6.
You will then see this prompt:
7.
At the above prompt:
a.
Type
y
(for Yes)
b.
Select
Transfer
|
File
in HyperTerminal.
c.
Enter the appropriate filename and path for the OS image.
d.
Select the
Xmodem
protocol (and not the 1k Xmodem protocol).
e.
Click on
[Send]
.
If you are using HyperTerminal, you will see a screen similar to the
following to indicate that the download is in progress:
Summary of Contents for ProCurve 4104GL
Page 2: ......
Page 26: ...xxiv Getting Started Need Only a Quick Start ...
Page 34: ...1 8 Selecting a Management Interface Advantages of Using HP TopTools for Hubs Switches ...
Page 50: ...2 16 Using the Menu Interface Where To Go From Here ...
Page 172: ...8 24 Time Protocols SNTP Messages in the Event Log ...
Page 240: ...10 30 Configuring for Network Management Applications CDP ...
Page 288: ...11 48 Port Based Virtual LANs VLANs and GVRP GVRP ...
Page 480: ...C 38 Troubleshooting Restoring a Flash Image ...
Page 486: ...D 6 MAC Address Management Determining MAC Addresses ...
Page 490: ......
Page 502: ...12 Index ...
Page 503: ......