A-2
ProCurve Secure Access 700wl Series Installation and Getting Started Guide
Troubleshooting
No traffic through access
point
No connection
1. Check cabling to access point.
2. Use cross-over cable if required
3. Check power to Access Point
Access point requires server
for WEP Key
Create Identity Profile for MAC address
of access point that allows this traffic for
each access point.
Access Point requires
configuration
If Access point uses static IP or wants
a dynamic IP address from network
DHCP server, make sure 700wl Series
system system is not doing NAT for
Access Point (create Identity Profile for
MAC address of Access Point that
allows Real IP Mode)
No initial web page
Access Controller Module
sees no web request
Use a browser to request http://1.1.1.1
Browser problems
Internet Explorer 5.01 with DLL
schannel.dll version 4.86.1959.1877 is
known to have broken SSL
Certain downrev versions of MAC
OS/X browsers have broken SSL
Table A-1. Troubleshooting Guide (Continued)
Symptom(s)
Probable Cause
Recommended Action