Sw
it
ch Spec
ifi
cati
ons
Switch Specifications
Environmental
Non-PWR 2600 Series Operating
Non-Operating
Temperature
0
°
C to 55
°
C (32
°
F to 131
°
F) -40
°
C to 70
°
C (-40
°
F to 158
°
F)
Relative humidity
15% to 95% at 40
°
C (104
°
F)
15% to 90% at 65
°
C (149
°
F)
(non-condensing)
Maximum altitude
4.6 Km (15,000 ft)
4.6 Km (15,000 ft)
2600-PWR Series
Operating
Non-Operating
Temperature
0
°
C to 50
°
C (32
°
F to 122
°
F) -40
°
C to 70
°
C (-40
°
F to 158
°
F)
Relative humidity
15% to 95% at 40
°
C (104
°
F)
15% to 90% at 65
°
C (149
°
F)
(non-condensing)
BTU Ratings
Switch Model
Combined BTU
1
Switch only BTU
2600-8-PWR
649
228
2626-PWR
2288
921
2650-PWR
2288
921
2626
Non-PoE
341
2650
Non-PoE
341
1
Includes switch and maximum number of PoE powered devices
connected to the switch at 15.4 watts.
Acoustic
Non-PWR 2600 Series (J4899B/J4900B)
Geraeuschemission LwA=50 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19
Noise Emission LwA=50 dB at virtual work space according to DIN 45635 T.19
2600-PWR Series (J8164A/J8165A)
Geraeuschemission LwA=53 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19
Noise Emission LwA=53 dB at virtual work space according to DIN 45635 T.19
2600-8-PWR switch (J8762A)
Geraeuschemission LwA=55 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19
Noise Emission LwA=55 dB at virtual work space according to DIN 45635 T.19
A-2
Summary of Contents for ProCurve Series 2600
Page 2: ......
Page 3: ...ProCurve Series 2600 Switches Installation and Getting Started Guide ...
Page 60: ... This page is intentionally unused ...
Page 82: ... This page is intentionally unused ...
Page 92: ... This page is intentionally unused ...
Page 108: ... This page is intentionally unused ...
Page 115: ......