9
Specifications
Specifications
Physical
Electrical
The ProCurve Switch zl Internal Power Supply automatically adjusts to any
voltage between 100-127, and 200-240 (J8712A) and 200-240 (J8713A) volts and
either 50 or 60 Hz.
Environmental
1
Operating ambient temperature is limited to 40
°
C (104
°
F) under certain
configurations. For more information, refer to
Switch Installation and
Getting Started Guide
for your switch.
Width:
20.1 cm (7.9 in)
Depth:
15.0 cm (5.9 in)
Height:
12.8 cm (5.1 in)
Weight:
1.5 kg (3.3 lbs)
J8712A
J8713A
AC voltage:
100-127 volts
200-240 volts
200-240 volts
Maximum current:
12 A max
5 A max
10 A max
Frequency range:
50/60 Hz
50/60 Hz
50/60 Hz
PoE output wattage:
273 W
273 W
900 W
Operating
Non-Operating
Temperature:
1
0
°
C to 55
°
C (32
°
F to 131
°
F)
-40
°
C to 70
°
C (-40
°
F to 158
°
F)
Relative humidity:
(non-condensing)
15% to 95% at 40
°
C (104
°
F)
15% to 90% at 65
°
C (149
°
F)
Maximum altitude:
J8712A
4.6 km (15,000 ft)
4.6 km (15,000 ft)
J8713A
3.0 km (10,000 ft)
4.6 km (15,000 ft)
Summary of Contents for procurve switch zl
Page 1: ...Installation Guide www procurve com ProCurve Switch zl Internal Power Supply ...
Page 2: ......
Page 3: ...ProCurve Switch zl Internal Power Supplies Installation Guide ...
Page 6: ......
Page 16: ...10 Specifications Safety EN60950 CSA 22 2 No 60950 IEC 60959 UL 60950 ...
Page 22: ...16 Safety Information Japan Safety Information Japan Ja pa n P o w er C o r d Wa r n i n g ...
Page 23: ...17 Safety Information China Safety Information China ...
Page 30: ......
Page 31: ......