D
Specifications
MT Specifications
Table D-1
Specifications
Chassis
Height
Width
Depth
14.0 in
6.7 in
13.4 in
355 mm
170 mm
340 mm
Approximate Weight
14.0 lb
6.35 kg
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
NOTE:
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct
sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options
installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
Power Supply
Operating Voltage Range
Rated Voltage Range
1
Rated Line Frequency
Operating Line Frequency
90-264 VAC
100-240 VAC
50-60 Hz
47-63 Hz
Standard Efficiency
280W active PFC
80 PLUS Bronze
280W active PFC
280W active PFC; 82/85/82% efficient at 20/50/100%
load (115V)
280W active PFC; 82/85/82% efficient at 20/50/100%
load (230V)
80 PLUS Platinum
280W active PFC
280W active PFC; 90/92/89% efficient at 20/50/100%
load (115V)
280W active PFC; 91/93/90% efficient at 20/50/100%
load (230V)
130 Appendix D Specifications