HP DL180 G6 Intel® Xeon® E5520 (2.26GHz/4-core/8MB/80W) Processor Kit

508342-B21

NOTE:

 HT indicates that the processor model supports Intel® Hyper-Threading

Technology.

NOTE:

 Turbo indicates the maximum potential frequency increment when using Intel®

Turbo Boost Technology, with 4, 3, 2, and 1 cores active.

NOTE:

 DDR3 speed is the maximum memory speed of the processor. Actual memory

speed may depend on the quantity and type of DIMMs installed.

NOTE:

 For the Intel 5000 Series, the letter preceding the model number indicates the

performance/wattage of the processor. "X" denotes High Performance/Wattage; "E"
denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower
Wattage.

 

HP Memory

Registered RDIMMs

HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit

500656-B21

HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit

500658-B21

HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit

593339-B21

HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit

500666-B21

HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power
Memory Kit

604504-B21

HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power
Memory Kit

604506-B21

HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit

500662-B21

HP 16GB (1x16GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 LP
Memory Kit

627812-B21

Unregistered with ECC UDIMMs

 

HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit

500668-B21

HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit

500670-B21

HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit

500672-B21

HP 4GB (1x4GB) Dual Rank x8 PC3L-10600 (DDR3-1333) Unbuffered CAS-9 Low Power
Memory Kit

619488-B21

NOTE:

 All DDR3 memory option kits consist of one DIMM per kit. For detailed memory

configuration rules and guidelines, please use the Online DDR3 Memory Configuration
Tool: 

www.hp.com/go/ddr3memory-configurator

NOTE:

 Kits described as LP include Low Power DIMMs. For more information on ProLiant

Energy Efficient Features, see:

http://h18004.www1.hp.com/products/servers/platforms/energyefficient/

 

HP Optical Drives

HP Slim 12.7mm SATA DVD-ROM Optical Drive

481041-B21

HP Slim 12.7mm SATA DVD-RW Optical Drive

481043-B21

NOTE:

 Optical drives can be installed in front, on 4 & 8 bay hard drive models.

NOTE:

 Optical drives can be installed in 12 and 25 drive model with the addition of rear

option kit (P/N 515826-B21).

 

QuickSpecs

HP ProLiant DL180 Generation 6 (G6)

Core Options

DA - 13248   Worldwide — Version 53 — September 24, 2012

Page  22

Summary of Contents for ProLiant DL180 G

Page 1: ...Low Profile Card Slot 4 Optional DVD RW or DVD ROM drive 4 PCI Expansion Card Slot 5 Front USB Ports 2 5 PCI Expansion Card Slot 6 Non Hot Plug Non Redundant fans 4 fans 6 UID LED Button 7 Air Baffle 7 Optional LO100i 10 100 Mbps LAN port for IPMI management RJ 45 8 PCI Cage 9 System Board 8 LAN Port 9 LAN Port 10 2 Rear USB 2 0 Ports 11 VGA Port 12 Serial Port What s New Support for HP 3TB 3G SAT...

Page 2: ...03 1 60GHz 4 core 4MB 80W DDR3 1066 Processor NOTE Available through Configure To Order only See Factory Integration Models section for more details Intel Xeon L5630 2 13GHz 4 core 12MB 40W DDR3 1066 HT Turbo 1 1 2 2 Processor Intel Xeon E5540 2 53GHz 4 core 8MB 80W DDR3 1066 HT Turbo 1 1 2 2 Processor Intel Xeon E5520 2 26GHz 4 core 8MB 60W DDR3 1066 HT Turbo 1 1 2 2 Processor NOTE HT indicates t...

Page 3: ...ss 4 0 N Full Length Full Height 4 x4 PCI Express 3 0 N Full Length Full Height 2 PCI X Dynamic 1 N Full Length Full Height 3 PCI X Dynamic 2 N Full Length Full Height NOTE All slots can accept universal keyed PCI cards NOTE Only PCI X support is available in slot 4 supporting PCI X cards PCI legacy cards are not supported Default bus assignment Inserting cards with PCI bridges may alter the actua...

Page 4: ...of 256 MB cache battery kit and Smart Array Advanced Pack License Key upgrade P N 516471 B21 is required to enable RAID 6 6 0 NOTE To achieve highest possible stated transfer rate please make sure the firmware on the drive bays backplanes and HP Smart Array controller up to date Latest firmware are available to download from HP support web site NOTE All Hard drive bay options except 4LFF require H...

Page 5: ...tifications IPMI 2 0 Compliant Server Power Cords One 6 Highline IEC IEC power cord ships standard NOTE HP ProLiant DL servers no longer ship standard with NEMA power cords P N 163719 002 that allow connection to 110V US wall outlets in a home or office ProLiant DL servers are primarily connected to PDU s in data center racks so they now ship standard with a PDU power cord 416151 B21 If a user wis...

Page 6: ...ciency 1200Watts Common Slot 48V DC Power Supply HP s ProLiant Common Slot Power supplies 460W 750W meet multiple Energy Efficiency Initiatives Climate Savers Computing Initiative GOLD ECOS Consulting 80PLUS GOLD and plans on offering models that meet the Energy Star for Server requirements when they are published HP s ProLiant Common Slot Power supplies 1200W meet multiple Energy Efficiency Initi...

Page 7: ...s which are very suitable for this class of server SIM SMH agents providers and a SmartStart like deployment CD called Easy Set up which greatly simplifies server set up Additionally the DL100 and SL100 G6 models support the SmartStart Scripting Toolkit SSSTK an automated scalable deployment utility Information on core management supported on ProLiant 100 series G6 servers can be found at these UR...

Page 8: ...nual installation Windows 2003 Server Windows 2008 Server and Linux drivers specific OS support varies by server Refer to each server s QuickSpecs for supported versions HP Insight Diagnostics AutoRun Array Configuration Utility ACU has been combined with Array Diagnostics Utility ADU to offer both configuration of array controllers and storage devices and testing of array controller hardware Smar...

Page 9: ...er on password Setup password Diskette boot control Secure Sockets Layer SSL Secure Shell SSH Warranty This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners Hardware diagnostic support and parts replacement is available for three years from date of purchase Support for software and initial setup is available for ...

Page 10: ... Integrity servers hosted on a Windows CMS It automates the process of deploying and provisioning server software enabling companies to quickly and easily adapt to changing business demands Insight Control server deployment includes software optimizations for HP servers including the HP scripting toolkits configuration jobs for leading industry standard operating systems sample unattended files an...

Page 11: ... scheduler the HP MPI parallelization library Also included are the HP Unified Parallel C compiler and the HP Shmem library as well as the execution environments for the libraries and compiler HP HPC Linux Value Pack Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration customization integration and deployment services for HP servers and storage products Custome...

Page 12: ...ons enable customers to optimize technology operations minimize risk and drive better business outcomes with easy to buy easy to use scalable support packages for servers storage networking and software Optimized Care Package Supports maintaining servers at optimum performance availability HP ProLiant Server Hardware Installation Provides for the basic hardware installation of HP branded servers s...

Page 13: ...stallation of HP branded servers storage devices and networking options to assist you in bringing your new hardware into operation in a timely and professional manner http h20195 www2 hp com V2 GetPDF aspx 5981 9356EN pdf 3 Year HP 13x5 4 hour Response Hardware Support Onsite Service Delivers increased equipment availability and productivity with rapid remote support and onsite response for your H...

Page 14: ...E Upgrading to 8 Hot Plug SATA SAS hard drives requires the addition of a HP 2U G6 8HDD LFF DL18X KIT P N 506924 B21 storage controller Smart Array P410 256MB recommended and two Internal SATA SAS cables mini SAS cable P N 496013 B21 HP ProLiant DL180 G6 E5606 1P 4GB R 460W PS Entry Server 635199 xx1 Processor 1 Intel Xeon E5606 2 13GHz 4 core 8MB 80W DDR3 800 Processor Cache Memory 8MB shared L3 ...

Page 15: ...ess Day Parts replacement 0 Years Labor 0 Years Onsite support HP ProLiant DL180 G6 L5630 1P 4GB L P410 256 8 LFF 460W PS Server 590636 xx1 Processor 1 Intel Xeon L5630 2 13GHz 4 core 12MB 40W DDR3 1066 HT Turbo 1 1 2 2 Processor Cache Memory 12MB shared L3 cache Memory 4GB 1 x 4GB PC3L 10600R 9 RDIMM NOTE Total 12 DIMM slots Network Controller HP NC362i Integrated Dual Port Gigabit Server Adapter...

Page 16: ...ack 2U Warranty Server Warranty includes 3 Years Next Business Day Parts replacement 0 Years Labor 0 Years Onsite support Twenty Five Drive SAS Models HP ProLiant DL180 G6 E5645 2P 16GB R 750W RPS Perf Server 635200 xx1 Processor 2 Intel Xeon E5645 2 40GHz 6 core 12MB 80W DDR3 1333 HT Turbo 1 1 1 1 2 2 Processor Cache Memory 12MB shared L3 cache Memory 16GB 4 x 4GB PC3 10600R 9 RDIMM NOTE Total 12...

Page 17: ...quired to enable RAID 6 6 0 Hard Drive None Ship Standard Internal Storage 25 0TB 25 x 1 0TB Hot Plug 2 5 SATA hard drives Maximum 25 0TB 25 x 1 0TB Hot Plug 2 5 SAS hard drives Maximum 20 0TB 25 x 800GB Hot Plug 2 5 SAS SSD Maximum 10 0TB 25 x 400GB Hot Plug 2 5 SATA SSD Maximum Optical Drive None ship standard Power Supply 750 W common slot power supply Form Factor Rack 2U Warranty Server Warran...

Page 18: ...100 PCI X slots are 64 bits 133 MHz capable if only one PCI X card is installed in the server NOTE Optional FL FH option kit includes Slot 1 full length full height slot One HP SATA Embedded Cable Kit One Highline IEC Power Cord 4 Non Hot Plug Fans Rack 2U 3 5 in 8 89 cm Tool less Fixed Rails Hot Plug SFF Models HP ProLiant DL180 G6 SFF Configure to order Server 594911 B21 Factory Integrated Model...

Page 19: ...Kit 500658 B21 HP 4GB 1x4GB Single Rank x4 PC3L 10600 DDR3 1333 Registered CAS 9 Low Power Memory Kit 604504 B21 HP 4GB 1x4GB Single Rank x4 PC3 10600 DDR3 1333 Registered CAS 9 Memory Kit 593339 B21 HP 8GB 1x8GB Dual Rank x4 PC3L 10600 DDR3 1333 Registered CAS 9 Low Power Memory Kit 604506 B21 HP 16GB 1x16GB Quad Rank x4 PC3 8500 DDR3 1066 Registered CAS 7 Memory Kit 500666 B21 HP 16GB 1x16GB Dua...

Page 20: ...188 B21 HP 750W Common Slot Platinum Hot Plug Power Supply Kit 593831 B21 HP 1200W Common Slot 48VDC Hot Plug Power Supply Kit 437573 B21 CAUTION Optional Power Supplies used for Redundancy MUST match the original supplied power supply Upgrades for more power headroom when replacing the original power supplies must match if purchased for redundancy Option Kits contain optional power supply an IEC ...

Page 21: ...1 506924 B21 HP DL180 G6 Rear 2 Large Form Factor Drive Kit NOTE Supports 12 hard drive server models only Hard Drives not included NOTE This option replaces the 2 Full Length Full Height x8 PCIe slots 488234 B21 HP DL180 G6 2PCI E x8 Full Height Upgradeable Option Kit NOTE This option provides 2 Full Length Full Height x8 PCIe slots 497145 B21 HP DL180 G6 PCI E x16 Upgradeable Option Kit NOTE Thi...

Page 22: ...ow Power Memory Kit 604506 B21 HP 8GB 1x8GB Dual Rank x4 PC3 10600 DDR3 1333 Registered CAS 9 Memory Kit 500662 B21 HP 16GB 1x16GB Dual Rank x4 PC3L 10600 DDR3 1333 Registered CAS 9 LP Memory Kit 627812 B21 Unregistered with ECC UDIMMs HP 1GB 1x1GB Single Rank x8 PC3 10600 DDR3 1333 Unbuffered CAS 9 Memory Kit 500668 B21 HP 2GB 1x2GB Dual Rank x8 PC3 10600 DDR3 1333 Unbuffered CAS 9 Memory Kit 500...

Page 23: ...v html Worldwide SATA Hot Plug 2 5 Enterprise Mainstream Solid State Drives HP 400GB 3G SATA MLC SFF 2 5 inch Enterprise Mainstream 3yr Warranty Solid State Drive 636597 B21 HP 200GB 3G SATA MLC SFF 2 5 inch Enterprise Mainstream 3yr Warranty Solid State Drive 636595 B21 HP 100GB 3G SATA MLC SFF 2 5 inch Enterprise Mainstream 3yr Warranty Solid State Drive 636593 B21 SATA Hot Plug 3 5 Midline MDL ...

Page 24: ...12244_div html Worldwide 6G SAS Hot Plug Enterprise Performance Solid State Drives HP 400GB 6G SAS SLC SFF 2 5 inch Enterprise Performance 3yr Warranty Solid State Drive 632494 B21 HP 200GB 6G SAS SLC SFF 2 5 inch Enterprise Performance 3yr Warranty Solid State Drive 632492 B21 6G SAS Hot Plug Enterprise Mainstream Solid State Drives HP 800GB 6G SAS MLC SFF 2 5 inch Enterprise Mainstream 3yr Warra...

Page 25: ...ion http h18000 www1 hp com products quickspecs 14038_div 14038_div html Worldwide HP Networking Gigabit Ethernet Adapters HP NC112T PCI Express Gigabit Server Adapter 503746 B21 HP NC360T PCI E Dual Port Gigabit Server Adapter 412648 B21 HP NC364T PCI E Quad Port Gigabit Server Adapter NOTE Does not support Windows 2000 435508 B21 HP NC365T 4 port Ethernet Server Adapter 593722 B21 HP NC373F PCI ...

Page 26: ...3211 B21 HP InfiniBand 4X QDR ConnectX 2 PCIe G2 Dual Port HCA 592520 B21 HP InfiniBand 4X DDR ConnectX 2 PCIe G2 Dual Port HCA 592521 B21 NOTE Please see the QuickSpecs for additional information http h18000 www1 hp com products quickspecs 13078_div 13078_div html QuickSpecs HP ProLiant DL180 Generation 6 G6 Core Options DA 13248 Worldwide Version 53 September 24 2012 Page 26 ...

Page 27: ...tries except China and Japan For China and Japan should order the physical equivalent TC213AAE HP Insight Control for Linux including 1yr 24x7 Support Single Server License TC209A HP Insight Control for Linux Media Kit NOTE This optional Media pack DVD contains the ISO image for HP Insight Control for Linux HP Systems Insight Manager HP Insight Control power management HP Insight Control virtual m...

Page 28: ...tomer will receive a printed end user license agreement and license entitlement certificate via physical shipment The license entitlement certificate must be redeemed online in order to obtain a license key Customer also will receive a support agreement BD476A HP Insight Cluster Management Utility Media NOTE Order a minimum of one license per cluster to purchase media including software and docume...

Page 29: ...e Graphic Power Adapter Kit can support up to 150 Watts 533955 B21 HP Security HP Trusted Platform Module Option 488069 B21 NOTE The TPM Trusted Platform Module is a microcontroller chip that can securely store artifacts used to authenticate the server platform These artifacts can include passwords certificates and encryption keys Windows BitLocker Drive Encryption BitLocker is a data protection f...

Page 30: ... Series Battery NOTE To enable BBWC on the 256MB cache NOTE Supported on HP Smart Array P212 Controller HP Smart Array P410 Controller and HP Smart Array P411 Controller only 462969 B21 HP 8484 to Mini SAS 33in Cable Assembly NOTE Cable for use connecting the Smart Array P800 Controller to internal hard disk drives on select HP ProLiant G6 Servers 591734 B21 HP Smart Array Hot Plug Advance Pack fo...

Page 31: ...tor Express V5 for 1 Server E LTU TC333AAE NOTE Only one of these Data Protector Express base products is required To see available options http www hp com go dataprotectorexpress HP Tape Backup NOTE For the complete range of tape drives autoloaders libraries and media see http www hp com go tape For hardware and software compatibility of HP tape backup products see http www hp com storage SPOCK H...

Page 32: ...eduplication HP D2D2502i Backup System NOTE 1 5TB of usable network disk backup capacity Network connected appliance with connectivity using the iSCSI protocol If the server requires a hardware iSCSI initiator the QLogic QLA4050 Host Bus Adapter is recommended EJ001C HP D2D2504i Backup System NOTE 3 0TB of usable network disk backup capacity Network connected appliance with connectivity using the ...

Page 33: ...E311A HP FC1242SR 4Gb 2 port PCIe Fibre Channel Host Bus Adapter AE312A SCSI HBA HP U320e SCSI Dual Channel Host Bus Adapter NOTE Recommended for MSL SCSI Tape Library connect AH627A Converged Network Adapter HP CN1000E Dual Port Converged Network Adapter AW520B HP CN1000Q Dual Port Converged Network Adapter BS668A HP CN1100E Dual Port Converged Network Adapter BK835A HP Disk Storage Systems MSA S...

Page 34: ...Please see the QuickSpecs for additional information http h18000 www1 hp com products quickspecs 14058_div 14058_div html Worldwide HP R1500 G3 Uninterruptible Power Supply UPS HP R1 5kVA G3 1U NA Uninterruptible Power System AF469A HP R1 5kVA G3 1U JP TW Uninterruptible Power System AF470A HP R1 5kVA G3 1U INTL Uninterruptible Power System AF471A NOTE Please see the QuickSpecs for additional info...

Page 35: ...iv html Worldwide Modular PDUs 1U 0U Up to 28 outlets HP 4 9kVA 24A High Voltage NA JP Modular Power Distribution Unit 252663 D72 HP 8 3kVA 40A High Voltage NA JP Modular Power Distribution Unit 252663 D73 HP 3 6kVA 16A High Voltage INTL Modular Power Distribution Unit 252663 B24 HP 7 3kVA 32A High Voltage INTL Modular Power Distribution Unit 252663 B31 NOTE Please see the following QuickSpecs for...

Page 36: ...ouse Kit 672097 D63 HP USB BFR with PVC Free AP INTL Keyboard Mouse Kit 672097 373 HP USB BFR with PVC Free INTL Keyboard Mouse Kit 672097 B33 HP USB BFR with PVC Free PORT Keyboard Mouse Kit 672097 133 HP USB BFR with PVC Free TURK Keyboard Mouse Kit 672097 143 HP USB BFR with PVC Free CZ Keyboard Mouse Kit 672097 223 HP USB BFR with PVC Free FIN Keyboard Mouse Kit 672097 353 HP USB BFR with PVC ...

Page 37: ...d Keyboard DT528A ABA HP Care Pack Services Hardware Services 4 Hour On site Service HP 3 year 4 hour 13x5 ProLiant DL18x Hardware Support UH271E HP 3 year 4 hour 24x7 ProLiant DL18x Hardware Support UH272E Hardware Services Next Business Day On Site Service HP 3 year Next business day ProLiant DL18x Hardware Support UH270E Hardware Services 6 Hour Call to Repair On Site Service HP 3 year 6 hour 2...

Page 38: ...ot mix Unbuffered memory UDIMMs with Registered memory RDIMMs Do not install DIMMs if the corresponding processor is not installed If only one processor is installed in a 2CPU system only half of the DIMM slots are available To maximize performance balance the total memory capacity between all installed processors It is not required but it is recommended to load the channels similarly if possible ...

Page 39: ...ximum speed of 1066MHz Mixing DIMM speeds is allowed but the system processor speed rules always override the DIMM capabilities If you do mix DIMM speeds the memory bus will default to the minimum clock rate of all DIMMs in the system even if the slower DIMM is on the other processor If you install 1x 1066MHz DIMM in channel 1 and 1x 1333MHz DIMM in channel 2 the maximum speed will be 1066MHz If y...

Page 40: ...ty Chnl 2 4 B 2GB DIMM 4 B empty Chnl 3 5 F empty 5 F empty Chnl 3 6 C 2GB DIMM 6 C empty Standard memory plus optional memory 1 CPU model 30GB consisting of three 3 2GB RDIMMs plus three 3 8GB RDIMMs 3x 2GB dual rank PC3 10600 RDIMMs 3x 8GB dual rank PC3 8500 RDIMMs CPU1 CPU2 slot population order slot population order Chnl 1 1 D 8GB DIMM 1 D empty Chnl 1 2 A 2GB DIMM 2 A empty Chnl 2 3 E 8GB DIM...

Page 41: ... D 4GB DIMM 1 D empty Chnl 1 2 A 4GB DIMM 2 A empty Chnl 2 3 E 4GB DIMM 3 E empty Chnl 2 4 B 4GB DIMM 4 B empty Chnl 3 5 F 4GB DIMM 5 F empty Chnl 3 6 C 4GB DIMM 6 C empty Standard memory replaced with optional memory 2 CPU model RDIMM maximum configuration 192GB consisting of twelve 12 16GB quad rank PC3 8500 RDIMMs and twelve 12 16 GB dual rank PC3L 10600R 9 RDIMMs CPU1 CPU2 slot population orde...

Page 42: ...6384MB For detailed memory configuration rules and guidelines please use the Online DDR3 Memory Configuration Tool www hp com go ddr3memory configurator DDR3 memory options part number decoder HP Memory Registered RDIMMs HP 2GB 1x2GB Dual Rank x8 PC3 10600 DDR3 1333 Registered CAS 9 Memory Kit 500656 B21 HP 4GB 1x4GB Dual Rank x4 PC3 10600 DDR3 1333 Registered CAS 9 Memory Kit 500658 B21 HP 4GB 1x...

Page 43: ...DDR3 1333 Unbuffered CAS 9 Memory Kit 500670 B21 HP 4GB 1x4GB Dual Rank x8 PC3 10600 DDR3 1333 Unbuffered CAS 9 Memory Kit 500672 B21 HP 4GB 1x4GB Dual Rank x8 PC3L 10600 DDR3 1333 Unbuffered CAS 9 Low Power Memory Kit 619488 B21 NOTE All DDR3 memory option kits consist of one DIMM per kit For detailed memory configuration rules and guidelines please use the Online DDR3 Memory Configuration Tool w...

Page 44: ...one year or three year warranty refer to the specific hard drive QuickSpecs for details SATA Hot Plug SFF 2 5 inch Midline MDL Drives Quantity Supported Position Supported Controller 1 0TB 3G SATA 7 2K 500GB 3G SATA 7 2K Up to 8 with 8 drive cage 1 8 HP Smart Array P212 Zero Memory Controller HP Smart Array P212 256 MB Controller HP Smart Array P410 256 MB Controller HP Smart Array P410 512 MB BBW...

Page 45: ... FBWC Controller HP Smart Array P800 512 BBWC Controller HP Smart Array Hot Plug Advance Pack for B110i SATA Hot Plug LFF 3 5 inch Entry ETY Drives Quantity Supported Position Supported Controller 250GB 3G SATA 7 2K Up to 8 with 8 drive cage 1 8 HP Smart Array P212 Zero Memory Controller HP Smart Array P212 256 MB Controller HP Smart Array P410 256 MB Controller HP Smart Array P410 512 MB BBWC Con...

Page 46: ...Smart Array P212 256 MB Controller HP Smart Array B110i Hot Plug Advance Pack for B110i SAS Hot Plug SFF 2 5 inch Midline MDL Drives Quantity Supported Position Supported Controller 1 0TB 6G SAS 7 2K 500GB 6G SAS 7 2K Up to 8 with 8 drive cage 1 8 HP Smart Array P212 Zero Memory Controller HP Smart Array P212 256 MB Controller HP Smart Array P410 256 MB Controller HP Smart Array P410 512 MB BBWC C...

Page 47: ...th 25 drive cage 1 25 HP Smart Array P212 256 MB Controller HP Smart Array P410 256 MB Controller HP Smart Array P410 512 MB BBWC Controller HP Smart Array P410 512 MB FBWC Controller HP Smart Array P410 1G FBWC Controller HP Smart Array P812 1G FBWC Controller HP Smart Array P800 512 BBWC Controller SAS Hot Plug LFF 3 5 inch Enterprise ENT Drives Quantity Supported Position Supported Controller 6...

Page 48: ...C Controller HP Smart Array P812 1G Flash Backed Cache Controller HP Smart Array P800 512 BBWC Controller Tape and Disk Backup NOTE For the complete range of tape drives autoloaders libraries and media including the internal fitting models see http www hp com go tape For the complete range of D2D Backup Systems see http www hp com go d2d For the complete range of RDX drives and media see http www ...

Page 49: ... MSL4048 MSL8096 MSL6000 External HP U320e SCSI Dual Channel Host Bus Adapter AH627A HP SAS Tape Autoloaders and Libraries 1 8 G2 Autoloader MSL2024 MSL4048 MSL8096 External HP Smart Array P212 ZM 1 ports Int 1 ports Ext PCIe x8 SAS Controller 462828 B21 HP Fibre Channel Tape Libraries MSL2024 MSL4048 MSL8096 MSL6000 External Please consult the EBS connectivity matrix at http www hp com go ebs for...

Page 50: ...tiator the QLogic QLA4050 Host Bus Adapter is recommended HP D2D Backup Systems Fibre Channel D2D4000fc External Direct server attach is not supported requires connection via SAN fabric See http www hp com storage SPOCK QuickSpecs HP ProLiant DL180 Generation 6 G6 Storage DA 13248 Worldwide Version 53 September 24 2012 Page 50 ...

Page 51: ...U Hr 1794 1773 1725 1725 1715 1715 1715 HP 750W Common Slot Gold Hot Plug Power Supply Kit Part Number 512327 B21 Input Voltage Range Vrms 100 to 240 Frequency Range Nominal Hz 50 60 Nominal Input Voltage Vrms 100 120 208 200 220 230 240 Maximum Rated Output Wattage 750 750 750 750 750 750 750 Nominal Input Current A rms 8 9 7 4 4 3 4 1 3 9 3 7 3 6 Max Rated Input Wattage Rating Watts 857 847 824 ...

Page 52: ...U Hr 1747 1722 1683 1682 1679 1678 1677 HP 750W Common Slot Platinum Hot Plug Power Supply Kit Part Number 593831 B21 Input Voltage Range Vrms 100 to 240 Frequency Range Nominal Hz 50 60 Nominal Input Voltage Vrms 100 120 208 200 220 230 240 Maximum Rated Output Wattage 750 750 750 750 750 750 750 Nominal Input Current A rms 8 6 7 1 4 2 4 0 3 8 3 6 3 4 Max Rated Input Wattage Rating Watts 841 828 ...

Page 53: ...65 Max Rated VA Volt Amp 1380 1350 1365 Efficiency 87 89 88 Power Factor N A Leakage Current mA N A Max Inrush Current A peak 20 25 35 Max Inrush Current duration mS 1 1 3 Maximum British Thermal Unit Rating BTU Hr 4713 4610 4662 Optional Country Power Cords and Jumper Cords WW HP C20 C13 WW 250V 15Amp 2 0m Jumper Cord AF590A Brazil HP C13 NBR 14136 BR 250V 10Amp 1 83m Power Cord AF591A QuickSpecs...

Page 54: ...er ratings use the Power Advisor which is available via the online tool located at URL www hp com go proliant energy efficient Click on the system of interest Example DL180 G6 Follow the instructions of the next screens Power Supply Output per power supply Rated Steady State Power 460 W at 100 VAC 750 W at 100 VAC 460 W at 200 VAC 750 W at 200 VAC Maximum Peak Power 460 W at 100 VAC 750 W at 100 V...

Page 55: ... LpAm when the product is operating in a 23 C ambient environment Noise emissions were measured in accordance with ISO 7779 ECMA 74 and declared in accordance with ISO 9296 ECMA 109 Idle LWAd 5 3 B LpAm 38 dBA Operating LWAd 5 3 B LpAm 38 dBA NC362i Integrated Dual Port Gigabit Server Adapter Network Interface Integrated 10 100 1000BASE T Transceiver Combines a triple speed IEEE 802 3TM Compliant ...

Page 56: ...ID 1 1 0 Striping Mirroring RAID 0 Striping Smart Array P410 410i Controller Disk Drive and Enclosure Interface 6Gb s SAS Serial Attached SCSI 3Gb s SATA Serial ATA SAS Connectors 2 internal Mini SAS x8 wide port connectors Cache Memory Speed DDR2 533MHz with 40 or 72 bit wide bus provides up to 4 2 GB s maximum bandwidth Server Interface x8 2 5G PCIe 2 0 provides 2GB s maximum bandwidth SAS Speed...

Page 57: ... be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2012 Hewlett Packard Development Company L P The information contained herein is subject to change without notice Microsoft and Windows NT are US registered trademarks of Microsoft Corporation Intel the Intel logo Xeon and Xeon Inside are trademarks of Intel Corpor...

Reviews: