Installing and Configuring HP RSO with Oracle Database Servers

 

 

managing RSO with 
Insight Manager 

 

The RSO solution environment can be easily managed through the powerful 

Insight Manager

 tool.   

Insight Manager 7

 monitors the Recovery Server Option.  When the Recovery Server Option 

changes status, the Management Agents send an SNMP trap to the 

Insight Manager

.  RSO is 

supported by Management Agents version 5.40 or higher. 

The 

Insight Manager

 storage agents provide an event for the RSO status called, “Storage system 

recovery option status change”.  Anytime the RSO status changes, the event and the current status 
are sent out.  The following values are possible for 

RSO Status

− 

OK -

  RSO is installed and the other server is working correctly. 

− 

Secondary Running - Auto -

 RSO is installed, but the secondary (standby) server is 

running in place of the primary server. The secondary server assumed control 
automatically. 

− 

Secondary Running - User -

 RSO is installed, but the secondary (standby) server is 

running in place of the primary server. The secondary server assumed control via manual 
intervention. 

− 

Link Down -

 RSO is installed, but the communications link to the secondary (standby) 

server is down. 

− 

No Secondary -

 RSO is installed, but the communications link to the secondary (standby) 

server has never been established. 

− 

Disabled -

 RSO is installed, but it has been disabled by software. This is done to 

temporarily prevent the secondary server from taking over when the primary server is 
brought down. This is used to perform maintenance and other tasks on the primary server. 

− 

Not Configured -

 RSO is supported, but not configured on this storage system. 

− 

Not Supported -

 RSO is not supported for this storage system. 

− 

Daemon Down - OK -

 RSO is installed, but the RSO operating system daemon is not 

running. The last RSO status was OK. 

− 

Daemon Down - Link Down -

 RSO is installed, but the RSO operating system daemon 

is not running. The last RSO status was Link Down. 

− 

Daemon Down - No Secondary -

 RSO is installed, but the RSO operating system 

daemon is not running. The last RSO status was No Secondary. 

− 

Daemon Down - Disabled -

 RSO is installed, but the RSO operating system daemon is 

not running. The last RSO status was 

Disabled

− 

Unknown -

 The Storage Agents cannot determine the RSO status for this storage system. 

 

For detailed information on 

Insight Manager 

support for RSO, check the 

Insight Manager

 User 

Guide and help files. 

 

conclusion 

 

The 

ProLiant

 Essentials RSO Pack is an entry-level high availability software that provides reliable 

protection and increased uptime against hardware and operating system failures. To protect a 
customer’s vital Oracle9

i

 database investments—while preserving the overall IT budget—the 

ProLiant

 Essentials RSO Pack, with 

ProLiant

 servers and 

Smart Array

 Cluster Storage, is the ideal 

high availability solution. 

Summary of Contents for ProLiant DL360 G2

Page 1: ...ng and configuring hp recovery server option with Oracle database servers table of contents abstract 2 audience 2 recovery server option 2 installing and configuring RSO with Oracle9i database server 4 managing RSO with Insight Manager 7 conclusion 7 appendix a 8 appendix b 9 appendix c 10 appendix d 11 references 12 ...

Page 2: ... the primary server and the other server functions as the hot standby recovery server RSO is installed in each server and the image of the operating system and the applications reside in the Smart Array cluster storage Applications are restarted on the recovery server when a fatal fault is detected in the hardware or the operating system of the primary server the RSO solution RSO provides a reliab...

Page 3: ... Array Storage Cluster Controller firmware is at a minimum revision of 1 34 or higher Smart Array 532 Controller Smart Array 5i Controller or Smart Array 5i Plus Controller firmware revision of 1 92 or higher RSO is supported with SmartStart version 5 5 and higher Note The HP Options ROM is also included on the RSO CD running Oracle9i database with RSO Oracle9i database provides performance securi...

Page 4: ...ry Server Upgrade the system and Options ROM revision for the ProLiant server and the Smart Array Storage Cluster It is required that the Smart Array Storage Cluster Controller firmware is at a minimum revision of 1 34 or higher HP Options ROM is included on the Recovery Server Option Pack CD See Appendix A for upgrading the ROMs Configure the drive array and logical drives See Appendix C Guidelin...

Page 5: ... Self Test POST press F8 to go into Option ROM Configuration for Arrays ORCA menu From the ORCA menu select Configure Recovery Server Option menu item This menu option will not be present if ROM is not updated or the boot drive is not in Smart Array Storage Select to make this the Standby server Select a timeout value default is 1 minute Note Make sure that the timeout value selected in the Standb...

Page 6: ...task bar Check that there are no RSO errors in the Windows Event Logs For Linux Issue the following shell command to verify that the RSO daemon is running ps ae grep RSO Check that there is no error message in the RSO log files grep cpqssd var log messages more the standby server status is at Ready Once the Primary Server has booted and the drivers daemons are running check the status screen on th...

Page 7: ... Disabled RSO is installed but it has been disabled by software This is done to temporarily prevent the secondary server from taking over when the primary server is brought down This is used to perform maintenance and other tasks on the primary server Not Configured RSO is supported but not configured on this storage system Not Supported RSO is not supported for this storage system Daemon Down OK ...

Page 8: ...is complete 2 Power on the primary server 3 Insert the RSO Pack CD 4 Allow the server to boot 5 The system will boot to the Options ROMPaq and the Options ROMPaq dialog box will be displayed 6 Press the Enter key to start the upgrade process 7 Follow the on screen instructions for controller firmware upgrade selections 8 Select ALL SA 5i SA 532 Ctlr s for firmware upgrade Press the Enter key to fl...

Page 9: ...soft operating systems 1 Insert the RSO Pack CD into the CD ROM drive 2 Click Start and Select Run from the menu if auto run does not start automatically 3 Enter CD ROM drive letter W2K_NT4 setup exe in the Open field and Click OK 4 Follow the on screen instructions 5 Enter the software license key when prompted for the serial number to install the software Linux Red Hat 7 2 Professional or Enterp...

Page 10: ...y Cluster Storage box The operating system and all applications will reside on the drives in the external storage The Smart Array Cluster Storage can hold fourteen drives The array configuration is going to depend on the database application environment For a typical On line transaction Processing OLTP type environment a total of three arrays with the following configuration may be used Array A Lo...

Page 11: ..._PASSWORDFILE is set Verify the value for the key ORA_ SID _AUTOSTART in the registry located at Hkey_Local_Machine software ORACLE HOMEXX where XX is Oracle Home Number WARNING Please use caution when attempting to modify the registry Editing the registry incorrectly can make the customer s system inoperative For Linux To automatically start the database on reboot create auto start shell scripts ...

Page 12: ...ervers proliantstorage sharedstorage sacluster in dex html Insight Management Suite http www compaq com products servers management index html HP Support Home http thenew hp com country us eng support html ActiveAnswers http activeanswers compaq com ActiveAnswers Render 0 2C1027 2C1 6 100 225 1 2C00 htm The information in this document is subject to change without notice Oracle is a U S registered...

Reviews: