HPE Trusted Platform Module 2.0 Guidelines
CAUTION:
Always observe the guidelines in this document. Failure to follow these guidelines can cause hardware
damage or halt data access.
When installing or replacing a TPM, observe the following guidelines:
• Do not remove an installed TPM. Once installed, the TPM is bound to the system board. If an OS is
configured to use the TPM and it is removed, the OS may go into recovery mode, data loss can occur, or
both.
• When installing or replacing hardware, Hewlett Packard Enterprise service providers cannot enable the
TPM or the encryption technology. For security reasons, only the customer can enable these features.
• When returning a system board for service replacement, do not remove the TPM from the system board.
When requested, Hewlett Packard Enterprise Service provides a TPM with the spare system board.
• Any attempt to remove the cover of an installed TPM from the system board can damage the TPM cover,
the TPM, and the system board.
• If the TPM is removed from the original server and powered up on a different server, data stored in the
TPM including keys will be erased.
• When using BitLocker, always retain the recovery key/password. The recovery key/password is required to
complete Recovery Mode after BitLocker detects a possible compromise of system integrity or system
configuration.
• Hewlett Packard Enterprise is not liable for blocked data access caused by improper TPM use. For
operating instructions, see the TPM documentation or the encryption technology feature documentation
provided by the operating system.
Installing and enabling the HPE TPM 2.0 Gen10 Kit
Installing the Trusted Platform Module board
Preparing the server for installation
Procedure
1.
Observe the following warnings:
WARNING:
To reduce the risk of personal injury, electric shock, or damage to the equipment, remove power
from the server by removing the power cord. The front panel Power On/Standby button does not
shut off system power. Portions of the power supply and some internal circuitry remain active until
AC power is removed.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
2.
Update the system ROM.
Locate and download the latest ROM version from the
Hewlett Packard Enterprise Support Center
. Follow the instructions on the website to update the system ROM.
3.
Power down the server (
on page 24).
4.
Remove all power:
HPE Trusted Platform Module 2.0 Guidelines
109