CAUTION:
Do not operate the server for long periods with the access panel open or removed. Operating the
server in this manner results in improper airflow and improper cooling that can lead to thermal
damage.
IMPORTANT:
For optimum cooling, install fans in all primary fan locations.
To replace the component, reverse the removal procedure.
Removing the primary PCI riser cage
CAUTION:
To prevent damage to the server or expansion boards, power down the server and remove all AC power
cords before removing or installing the PCI riser cage.
Procedure
1.
Back up all server data.
2.
Power down the server (
on page 24).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
a.
Extend the server from the rack (
Extend the server from the rack
b.
Remove the server from the rack (
Remove the server from the rack
on page 25).
5.
Remove the access panel (
on page 25).
6.
Remove the PCI riser cage.
Removing the primary PCI riser cage
27