Specifications
Environmental specifications
Specification
Value
System Inlet Temperature, Standard Operating
Support
—
Operating
10°C to 35°C (50°F to 95°F)
Non-operating
-30°C to 60°C (-22°F to 140°F)
Relative humidity (non-condensing)
—
Operating
Minimum to be the higher (more moisture) of -12°C
(10.4°F) dew point or 8% relative humidity
Maximum to be 24°C (75.2°F) dew point or 90%
relative humidity
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-condensing.
Altitude
—
Operating
3050 m (10,000 ft)
This value may be limited by the type and number of
options installed. Maximum allowable altitude change
rate is 457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft)
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305.0 m (1.8°F per 1000 ft)
to 3050 m (10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour
(36°F per hour). The upper limit and rate of change might be limited by the type and number of options
installed. System performance during standard operating support may be reduced if operating with a fan
fault or above 30°C (86°F).
The approved hardware configurations for this system are listed on the
.
136
Specifications