Environmental specifications
Specification
Value
System Inlet Temperature, Extended Ambient
Operating Support
—
—
For approved hardware configurations, the supported
system inlet range is extended to be:
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F
to 104°F)
All temperature ratings shown are for sea level with
an altitude derating of 1.0 °C per every 175 m (1.8°F
per every 574 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft).
1
—
For approved hardware configurations, the supported
system inlet range is extended to be:
40°C to 45°C (104°F to 113°F)
All temperature ratings shown are for sea level with
an altitude derating of 1.0 °C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft).
1
1
System performance may be reduced if operating in the extended ambient operating range or with a fan
fault.
The approved hardware configurations for this system are listed on the
.
Mechanical specifications
Specification
Value
Height
8.75 cm (3.44 in)
Depth
75.47 cm (29.71 in)
Width
44.54 cm (17.54 in)
Weight (maximum)
34.12 kg (75.23 lbs)
Weight (minimum)
18.45kg (40.67 lbs)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
• HPE 800W Flex Slot -48VDC Hot-plug Power Supply
• HPE 1600W Flex Slot Platinum Plus Hot-plug Power Supply
For detailed power supply specifications, see the QuickSpecs on the Hewlett Packard Enterprise website
http://www.hpe.com/info/proliant/powersupply
.
Environmental specifications
137