104
HP ProLiant DL560 Server User Guide
Is the System Power LED Green?
Answer Possible
Reasons Possible
Solutions
No
Power On/Standby button has not been
pressed firmly.
The power supply may not be inserted
properly, it may have a damaged
connector, or it may have failed.
The system may have experienced a
short.
The power converter module, system
board, SCSI backplane, and/or power
button/LED board may need to be
replaced.
The PCI riser cage is not fully seated.
Firmly press the Power On/Standby button.
Be sure that the power supply is undamaged
and is fully seated.
Be sure that all pins on connectors and
components are straight.
Reseat expansion boards.
Reseat the PCI riser cage.
Contact your authorized service provider for
assistance.
Yes
If the system power LED is green, refer to "Is the External Health LED Green? (on page
104)."
Is the External Health LED Green?
Answer Possible
Reasons Possible
Solutions
No, it is
amber
Power supply redundancy is lost due to a
power supply failure.
Be sure that the power supply is undamaged
and fully seated, or identify and replace the
failed power supply.
Contact your authorized service provider for
replacement parts and service.
No, it is
red
All installed power supplies have failed.
The system may have experienced a
short.
Contact your authorized service provider for
replacement parts and service.
Yes
If the external health LED is green, refer to "Is the Internal Health LED Green? (on page
105)."
HP CONFIDENTIAL
File Name: 303212-1new.doc Last Saved On: 11/4/02 10:51 AM
Summary of Contents for ProLiant DL560
Page 1: ...HP ProLiant DL560 Server User Guide ...
Page 54: ......
Page 78: ......
Page 81: ...Server Cabling 81 HP CONFIDENTIAL File Name 303212 1new doc Last Saved On 11 4 02 10 51 AM ...
Page 82: ......
Page 98: ......
Page 122: ......