Specifications 102
supply system earthing electrode conductor is connected.
•
This equipment must be located in the same immediate area (such as adjacent cabinets) as
any other equipment that has a connection between the earthed conductor of the same DC
supply circuit and the earthing conductor, and also the point of earthing of the DC system.
The DC system must be earthed elsewhere.
•
The DC supply source is to be located within the same premises as the equipment.
•
Switching or disconnecting devices must not be in the earthed circuit conductor between
the DC source and the point of connection of the earthing electrode conductor.
CAUTION:
To reduce the risk of electric shock or energy hazards:
•
This equipment must be installed by trained service personnel, as defined by the NEC and
IEC 60950-1, Second Edition, the standard for Safety of Information Technology
Equipment.
•
Connect the equipment to a reliably grounded SELV source. An SELV source is a
secondary circuit that is designed so normal and single fault conditions do not cause the
voltages to exceed a safe level (60 V DC).
•
The branch circuit overcurrent protection must be rated 24 A.
HPE 1500 W Common Slot Platinum Plus Hot-Plug Power
Supply (94% efficiency)
Specification
Value
Input requirements
Rated input voltage
200 to 240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
8.3 A at 200 VAC
Maximum rated input power
1652 W at 230 VAC input
BTUs per hour
5637 at 230 VAC input
Power supply output
Power supply output
1500 W
Rated steady-state power
1500 W at 200 V to 240 VAC
input
Maximum peak power
1500 W at 200 V to 240 VAC
input
Summary of Contents for ProLiant DL580 Gen9
Page 5: ...Contents 5 Documentation feedback 106 Index 107 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 98: ...Cabling 98 Front video USB cabling Power supply data cabling ...
Page 99: ...Cabling 99 Standby power cabling Systems Insight Display cabling ...